Assessing bowel preparation quality using the mean number of adenomas per colonoscopy
Open Access
- 19 June 2014
- journal article
- research article
- Published by SAGE Publications in Therapeutic Advances in Gastroenterology
- Vol. 7 (6) , 238-246
Abstract
The quality of the bowel preparation directly influences colonoscopy effectiveness. Quality indicators are widely employed to monitor operator performance and to gauge colonoscopy effectiveness. Some have suggested that the enumeration of the mean number of adenomas per colonoscopy (MNA) may be a more useful measure of bowel preparation quality, but evidence of the utility of this metric is limited. The relationship between bowel preparation quality and MNA was assessed. Records of adult patients, aged 50–74 years, who had undergone a screening colonoscopy in a 6 month period at a hospital-based endoscopy suite in New York City were examined. Excluded were those who were symptomatic or having a colonoscopy for surveillance. Patient and procedural characteristics and clinical findings were abstracted from the endoscopy database. Bowel preparation quality was recorded as excellent, good, fair and poor. Histology and size of polyps removed were gathered from pathology reports. MNA was calculated and incident rate ratios assessing the relationship between bowel preparation quality, MNA, and covariates was calculated using Poisson regression. A total of 2422 colonoscopies were identified; 815 (33.6%) were screening colonoscopies among average risk individuals, 50–74 years; 203 (24.9%) had ≥1 adenomas; and 666 (81.7%) had excellent/good preparation quality. Overall MNA was 0.34 [standard deviation (SD) 0.68] and MNA was greater among those >60 years [incident rate ratio (IRR) 1.89, 95% confidence interval (CI) 1.48–2.42), males (IRR 1.60, 95%CI 1.26–2.04) and those with good bowel preparation (IRR 2.54, 95%CI 1.04–6.16). Among those with ≥1 adenomas, MNA was 1.48 (SD 1.05) for excellent and 1.00 (SD 0.00) for poor quality preparation (p = 0.55). We found that MNA is sensitive to changes in bowel preparation with higher MNA among those with good bowel preparation compared with those with poor preparation. Our evidence suggests MNA was particularly sensitive when restricted to only those in whom adenomas were seen.Keywords
This publication has 34 references indexed in Scilit:
- Longer mean colonoscopy withdrawal time is associated with increased adenoma detection: evidence from the Bowel Cancer Screening Programme in EnglandEndoscopy, 2012
- Risk of colorectal adenomas and advanced neoplasia in Hispanic, black and white patients undergoing screening colonoscopyAlimentary Pharmacology & Therapeutics, 2012
- 724 Adenomas Under the Curve (AUC): A New Metric That Incorporates and Extends the Adenoma Detection Rate (ADR)Gastrointestinal Endoscopy, 2011
- Annual report to the nation on the status of cancer, 1975‐2006, featuring colorectal cancer trends and impact of interventions (risk factors, screening, and treatment) to reduce future ratesCancer, 2009
- Duration of the interval between the completion of bowel preparation and the start of colonoscopy predicts bowel-preparation qualityGastrointestinal Endoscopy, 2009
- The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented researchGastrointestinal Endoscopy, 2009
- A consensus document on bowel preparation before colonoscopy: Prepared by a Task Force From The American Society of Colon and Rectal Surgeons (ASCRS), the American Society for Gastrointestinal Endoscopy (ASGE), and the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES)Gastrointestinal Endoscopy, 2006
- Quality indicators for colonoscopyGastrointestinal Endoscopy, 2006
- Results of the first round of a demonstration pilot of screening for colorectal cancer in the United KingdomBMJ, 2004
- First-degree relatives of patients with advanced colorectal adenomas have an increased prevalence of colorectal cancerClinical Gastroenterology and Hepatology, 2003