Tip Clearance and Tip Vortex Cavitation in an Axial Flow Pump
Authors:
- 1 September 1997
- journal article
- Published by ASME International in Journal of Fluids Engineering
- Vol. 119 (3) , 680-685
Abstract
A combined study of tip clearance and tip vortex cavitations in a pump-type rotating machine is presented. Cavitation patterns are observed and cavitation inception is determined for various gap heights, clearance and blade geometries, and rotor operating conditions. An optimum clearance geometry is seen to eliminate clearance cavitation when the clearance edge is rounded on the blade pressure side. The gap height has a strong effect on clearance cavitation inception, but the trends vary considerably when other parameters are also modified. The gap height and clearance geometry have less influence on tip vortex cavitation but forward and backward blade skew is observed to reduce and increase tip vortex cavitation, respectively, as compared to a blade with no skew.Keywords
This publication has 5 references indexed in Scilit:
- Measurements of the Tip Clearance Flow for a High-Reynolds-Number Axial-Flow RotorJournal of Turbomachinery, 1995
- A Correlation of Leakage Vortex Cavitation in Axial-Flow PumpsJournal of Fluids Engineering, 1994
- Measurement and Prediction of Tip Clearance Flow in Linear Turbine CascadesJournal of Turbomachinery, 1993
- Laser Doppler velocimeter measurement in the tip region of a compressor rotorAIAA Journal, 1986
- Tip Clearance Cavitation in Shrouded Underwater PropulsorsJournal of Aircraft, 1966