Contribution of micro‐motion to backside wear in a fixed bearing total knee arthroplasty
Open Access
- 11 March 2016
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 34 (11) , 1933-1940
Abstract
This study seeks to identify important factors related to backside wear of tibial inserts in vivo and determine an appropriate wear model for backside wear. An IRB approved database was queried for tibial inserts of a single design from one manufacturer that exhibited evidence of rotatory motion on the backside of the polyethylene. These devices were measured for volumetric wear using a previously established protocol. Features including the change in locking lip width and measurement of micro‐motion marks were used to describe the motion pattern. Volumetric wear and implant characteristics were compared using linear regressions by modeling wear theories suggested by Archard and Wang to determine the most appropriate model for backside wear. The Wang model showed that duration, adjusted sliding distance, and cross‐shear index accounted for approximately 58% of the volumetric wear variation while adjusted sliding distance and duration in vivo accounted for approximately 35% of the volumetric wear variation in the Archard model. Patient weight (p = 0.750), patient BMI (p = 0.680), and backside area (p = 0.784) of the tibial insert were all found to be non‐significant in the Wang model. Similarly, patient weight (p = 0.233), patient BMI (p = 0.162), and backside area (p = 0.796) were found to be non‐significant in the Archard model. Multidirectional micro‐motion appears to contribute significantly to the wear of these components, supporting the Wang theory of cross‐shear for polyethylene wear. Cross‐shear of polymers on an unpolished titanium tray can lead to an increase in wear debris in the body. Care should be taken when designing locking mechanisms and tray designs. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1933–1940, 2016.Keywords
Funding Information
- National Science Foundation Graduate Research Fellowship (No. DGE-1313911)
This publication has 26 references indexed in Scilit:
- Damage and Wear: An Important Distinction in Rotating Platform Knee BearingsJournal of ASTM International, 2011
- Clinical Wear Measurement on Low Contact Stress Rotating Platform Knee BearingsThe Journal of Arthroplasty, 2008
- Mobile-bearing Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2006
- Comparison of the PFC sigma fixed-bearing and rotating-platform total knee arthroplasty in the same patientThe Journal of Arthroplasty, 2004
- Extraarticular Abrasive Wear in Cemented and Cementless Total knee ArthroplastyClinical Orthopaedics and Related Research, 2003
- Effects of contact area and stress on the volumetric wear of ultrahigh molecular weight polyethyleneWear, 2003
- Why Are Total Knee Arthroplasties Failing Today?Clinical Orthopaedics and Related Research, 2002
- Modular Tibial Insert MicromotionClinical Orthopaedics and Related Research, 1998
- Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prosthesesJournal of Applied Biomaterials, 1994
- Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prosthesesJournal of Biomedical Materials Research, 1983