A Sensor for Broken Wire Detection of Steel Wire Ropes Based on the Magnetic Concentrating Principle
Open Access
Abstract
Electromagnetic testing is the most widely used technique for the inspection of steel wire ropes. As one of the electromagnetic detecting approaches, the magnetic flux leakage (MFL) method has the best effect for the detection of broken wires. However, existing sensors based on MFL method still have some problems. (1) The size of the permanent magnet exciter is usually designed according to experience or rough calculation, and there is not enough depth analysis for its excitation performance; (2) Since the detectable angular range for a single Hall component is limited, Hall sensor arrays are often employed in the design of MFL sensors, which will increase the complexity of the subsequent signal processing due to the extensive use of Hall components; (3) Although the new magneto-resistance sensor has higher sensitivity, it is difficult to be applied in practice because of the requirement of the micron-level lift-off. To solve these problems, a sensor for the detection of broken wires of steel wire ropes based on the principle of magnetic concentration is developed. A circumferential multi-circuit permanent magnet exciter (CMPME) is employed to magnetize the wire rope to saturation. The traditional Hall sensor array is replaced by a magnetic concentrator to collect MFL. The structural parameters of the CMPME are optimized and the performance of the magnetic concentrator is analyzed by the finite element method. Finally, the effectiveness of the designed sensor is verified by wire breaking experiment. 1–5 external broken wires, handcrafted on the wire rope with a diameter of 24 mm, can be clearly identified, which shows great potential for the inspection of steel wire ropes.Keywords
Funding Information
- National Natural Science Foundation of China (51475249)
This publication has 23 references indexed in Scilit:
- Broken wire detection in coated steel belts using the magnetic flux leakage methodInsight - Non-Destructive Testing and Condition Monitoring, 2013
- Inspection method of cable-stayed bridge using magnetic flux leakage detection: principle, sensor design, and signal processingJournal of Mechanical Science and Technology, 2012
- An innovative design for using flexible printed coils for magnetostrictive-based longitudinal guided wave sensors in steel strand inspectionSmart Materials and Structures, 2011
- Key technique of a detection sensor for coal mine wire ropesMining Science and Technology (China), 2009
- Design of modified electromagnetic main-flux for steel wire rope inspectionNDT & E International, 2009
- FEM modelling techniques of magnetic flux leakage-type NDT for ferromagnetic plate inspectionsJournal of Magnetism and Magnetic Materials, 2006
- 3D FEM analysis in magnetic flux leakage methodNDT & E International, 2006
- Ultrasonic inspection of multi-wire steel strands with the aid of the wavelet transformSmart Materials and Structures, 2005
- A transducer made up of fluxgate sensors for testing wire rope defectsIEEE Transactions on Instrumentation and Measurement, 2002
- Wavelet-transform-based method of analysis for Lamb-wave ultrasonic NDE signalsIEEE Transactions on Instrumentation and Measurement, 2000