Dual-Mode FRET and BRET Sensors for Detecting cAMP Dynamics
Authors:
Open Access
- 12 September 2019
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 4 (13) , 15504-15511
Abstract
Genetically encoded fluorescent and luminescent indicators have revolutionized our ability to monitor physiology in real time, but the separate development of new sensors for each of these imaging modalities involves substantial effort and resources. Methods to rapidly engineer multimodal sensors would, therefore, significantly accelerate the diversification of sensors for simultaneous use in different systems and applications. We hypothesized that the enhanced Nano-lanterns could be incorporated into modular ratiometric sensors as an efficient approach to creating dual-mode fluorescent-luminescent sensors. As a proof-of-concept, we engineered an Epac1-based sensor that responds to cyclic adenosine monophosphate binding with a greater than 80% change in both Förster Resonance Energy Transfer and bioluminescent resonance energy transfer (BRET) modes. We also demonstrate that our new sensor reports cellular changes in G-protein-coupled signaling, and that the ratiometric BRET mode is bright enough for subcutaneous measurements in mice.Keywords
Funding Information
- National Center for Advancing Translational Sciences (UL1TR002529)
- National Eye Institute (R21EY026425)
- National Institute of Mental Health (F32MH115432)
This publication has 38 references indexed in Scilit:
- Development and Applications of Bioluminescent and Chemiluminescent Reporters and BiosensorsAnnual Review of Analytical Chemistry, 2019
- ATP-Independent Bioluminescent Reporter Variants To Improve in Vivo ImagingACS Chemical Biology, 2019
- Biased Signaling of the Mu Opioid Receptor Revealed in Native NeuronsiScience, 2019
- A platform of BRET-FRET hybrid biosensors for optogenetics, chemical screening, and in vivo imagingScientific Reports, 2018
- A Tandem Green–Red Heterodimeric Fluorescent Protein with High FRET EfficiencyChemBioChem, 2016
- Fourth-Generation Epac-Based FRET Sensors for cAMP Feature Exceptional Brightness, Photostability and Dynamic Range: Characterization of Dedicated Sensors for FLIM, for Ratiometry and with High AffinityPLOS ONE, 2015
- Optical properties of biological tissues: a reviewPhysics in Medicine & Biology, 2013
- β2-Adrenergic Receptor Signaling and Desensitization Elucidated by Quantitative Modeling of Real Time cAMP DynamicsJournal of Biological Chemistry, 2008
- Use of a cAMP BRET Sensor to Characterize a Novel Regulation of cAMP by the Sphingosine 1-Phosphate/G13 PathwayJournal of Biological Chemistry, 2007
- Transfecting Mammalian Cells: Optimization of Critical Parameters Affecting Calcium-Phosphate Precipitate FormationNucleic Acids Research, 1996