Development and Validation of a Transcreener Assay for Detection of AMP- and GMP-Producing Enzymes
Authors:
- 1 June 2010
- journal article
- research article
- Published by SAGE Publications in ASSAY and Drug Development Technologies
- Vol. 8 (3) , 339-350
Abstract
Screening of AMP- and GMP-producing enzymes such as phosphodiesterases (PDEs), ligases, and synthetases would be simplified by the ability to directly detect unmodified nucleoside monophosphates. To address this need, we developed polyclonal and monoclonal antibodies that recognize AMP and GMP with nanomolar sensitivity and high selectivity vs. the corresponding triphosphate and 3',5'-cyclic monophosphate nucleotides that serve as substrates for many enzymes in these classes. One of these antibodies was used to develop a Transcreener® AMP/GMP assay with a far red fluorescence polarization (FP) readout. This polyclonal antibody exhibited extremely high selectivity, with IC 50 ratios of 6,000 for ATP/AMP, 3,810 for cAMP/AMP, and 6,970 for cGMP/GMP. Standard curves mimicking enzymatic conversion of cAMP, cGMP, and ATP to the corresponding monophosphates yielded Z ' values of >0.85 at 10% conversion. The assay reagents were shown to be stable for 24 h at room temperature, both before and after dispensing. The Transcreener AMP/GMP FP assay was used for enzymatic detection of cGMP- and cAMP-dependent PDEs 4A1A, 3A, and 9A2 and ATP-dependent ligases, acetyl CoA synthetase, and ubiquitin-activating enzyme (UBE1). Shifts of >100 mP were observed in the linear part of the progress curves for all enzymes tested, and the PDE isoforms exhibited the expected substrate and inhibitor selectivity. These studies demonstrate that direct immunodetection of AMP and GMP is a flexible, robust enzyme assay method for diverse AMP- and GMP-producing enzymes. Moreover, it eliminates many of the shortcomings of other methods including the need for fluorescently labeled substrates, the low signal:background inherent in substrate depletion assays, and the potential for interference with coupling enzymes.Keywords
This publication has 30 references indexed in Scilit:
- Characterization and Optimization of a Red-Shifted Fluorescence Polarization ADP Detection AssayASSAY and Drug Development Technologies, 2009
- Evaluating PI3 Kinase Isoforms Using Transcreener™ ADP AssaysSLAS Discovery, 2008
- A High-Throughput Screen Measuring Ubiquitination of p53 by Human mdm2SLAS Discovery, 2007
- Miniaturization and Automation of an Ubiquitin Ligase Cascade Enzyme-Linked Immunosorbent Assay in 1,536-Well FormatASSAY and Drug Development Technologies, 2007
- A colorimetric assay method to measure acetyl-CoA synthetase activity: Application to woodchuck model of hepatitis virus-induced hepatocellular carcinomaJournal of Biochemical and Biophysical Methods, 2007
- Configuration of a Scintillation Proximity Assay for the Activity Assessment of Recombinant Human Adenine PhosphoribosyltransferaseASSAY and Drug Development Technologies, 2006
- Drug discovery in the ubiquitin–proteasome systemNature Reviews Drug Discovery, 2006
- Two Inotropes With Different Mechanisms of Action: Contractile, PDE-Inhibitory and Direct Myofibrillar Effects of Levosimendan and EnoximoneJournal of Cardiovascular Pharmacology, 2005
- Overcoming Compound Interference in Fluorescence Polarization-Based Kinase Assays Using Far-Red TracersASSAY and Drug Development Technologies, 2004
- Phosphodiesterase inhibitors: new opportunities for the treatment of asthma.Thorax, 1991