Relative performance of common biochemical indicators in detecting cigarette smoking
Abstract
Aims Many cities have banned indoor smoking in public places. Thus, an updated recommendation for a breath carbon monoxide (CO) cut‐off is needed that optimally determines smoking status. We evaluated and compared the performance of breath CO and semiquantitative cotinine immunoassay test strips (urine and saliva NicAlert®) alone and in combination.Design Cross‐sectional study.Setting Urban drug addiction research and treatment facility.Participants Ninety non‐treatment‐seeking smokers and 82 non‐smokers.Measurements Participants completed smoking histories and provided breath CO, urine and saliva specimens. Urine and saliva specimens were assayed for cotinine by NicAlert® and liquid chromatography‐tandem mass spectrometry (LCMSMS).Findings An optimal breath CO cut‐off was established using self‐report and LCMSMS analysis of cotinine, an objective indicator, as reference measures. Performance of smoking indicators and combinations were compared to the reference measures. Breath CO ≥5 parts per million (p.p.m.) optimally discriminated smokers from non‐smokers. Saliva NicAlert® performance was less effective than the other indicators.Conclusions In surveys of smokers and non‐smokers in areas with strong smoke‐free laws, the breath carbon monoxide cut‐off that discriminates most effectively appears to be ≥5 p.p.m. rather than the ≥10 p.p.m. cut‐off often used. These findings may not generalize to clinical trials, regions with different carbon monoxide pollution levels or areas with less stringent smoke‐free laws.Keywords
This publication has 23 references indexed in Scilit:
- Impact of tobacco control policies on exhaled carbon monoxide in non-smokersJournal of Epidemiology and Community Health, 2010
- Measuring tobacco use in a prison populationNicotine & Tobacco Research, 2010
- Dipstick tests for secondhand smoke exposureNicotine & Tobacco Research, 2010
- Breath carbon monoxide and semiquantitative saliva cotinine as biomarkers for smokingHuman Psychopharmacology: Clinical and Experimental, 2009
- Optimization and validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of nicotine, cotinine, trans-3′-hydroxycotinine and norcotinine in human oral fluidAnalytical and Bioanalytical Chemistry, 2009
- Optimal Serum Cotinine Levels for Distinguishing Cigarette Smokers and Nonsmokers Within Different Racial/Ethnic Groups in the United States Between 1999 and 2004American Journal of Epidemiology, 2008
- Contingency management for smoking cessation: Enhancing feasibility through use of immunoassay test strips measuring cotinineNicotine & Tobacco Research, 2008
- Validation of Self-Reported Smoking Status Using Saliva Cotinine: A Rapid Semiquantitative Dipstick MethodCancer Epidemiology, Biomarkers & Prevention, 2007
- Expired carbon monoxide levels in self‐reported smokers and nonsmokers in prisonNicotine & Tobacco Research, 2006
- Biomarkers of environmental tobacco smoke exposure.Environmental Health Perspectives, 1999