Quantification of SPIO nanoparticles in vivo using the finite perturber method
Open Access
- 30 November 2010
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 65 (5) , 1461-1469
Abstract
The susceptibility gradients generated by super‐paramagnetic iron oxide (SPIO) nanoparticles make them an ideal contrast agent in magnetic resonance imaging. Traditional quantification methods for SPIO nanoparticle‐based contrast agents rely on either mapping T values within a region or by modeling the magnetic field inhomogeneities generated by the contrast agent. In this study, a new model‐based SPIO quantification method is introduced. The proposed method models magnetic field inhomogeneities by approximating regions containing SPIOs as ensembles of magnetic dipoles, referred to as the finite perturber method. The proposed method was verified using data acquired from a phantom and in vivo mouse models. The phantom consisted of an agar solution with four embedded vials, each vial containing known but different concentrations of SPIO nanoparticles. Gaussian noise was also added to the phantom data to test performance of the proposed method. The in vivo dataset was acquired using five mice, each of which was subcutaneously implanted in the flanks with 1 × 105 labeled and 1 × 106 unlabeled C6 glioma cells. For the phantom data set, the proposed algorithm was generate accurate estimations of the concentration of SPIOs. For the in vivo dataset, the method was able to give estimations of the concentration within SPIO‐labeled tumors that are reasonably close to the known concentration. Magn Reson Med, 2011.Keywords
This publication has 43 references indexed in Scilit:
- Automated brain tumor segmentation using spatial accuracy-weighted hidden Markov Random FieldComputerized Medical Imaging and Graphics, 2009
- Measuring SPIO and Gd contrast agent magnetization using 3 T MRINMR in Biomedicine, 2009
- Detection and quantification of magnetically labeled cells by cellular MRIEuropean Journal of Radiology, 2009
- Ultrashort T relaxometry for quantitation of highly concentrated superparamagnetic iron oxide (SPIO) nanoparticle labeled cellsMagnetic Resonance in Medicine, 2009
- Limitations of calculating field distributions and magnetic susceptibilities in MRI using a Fourier based methodPhysics in Medicine & Biology, 2009
- MR tracking of transplanted cells with “positive contrast” using manganese oxide nanoparticlesMagnetic Resonance in Medicine, 2008
- Sensitive and automated detection of iron-oxide-labeled cells using phase image cross-correlation analysisMagnetic Resonance Imaging, 2008
- A novel technique for modeling susceptibility-based contrast mechanisms for arbitrary microvascular geometries: The finite perturber methodNeuroImage, 2008
- Improved focal liver lesion detection: Comparison of single-shot spin-echo echo-planar and superparamagnetic iron oxide (SPIO)-enhanced MRIJournal of Magnetic Resonance Imaging, 2007
- Three‐dimensional mapping of the static magnetic field inside the human headMagnetic Resonance in Medicine, 1996