Continuous subcutaneous insulin infusion: Special needs for children
Authors:
- 20 April 2017
- journal article
- review article
- Published by Hindawi Limited in Pediatric Diabetes
- Vol. 18 (4) , 255-261
Abstract
Continuous subcutaneous insulin infusion (CSII) is a very common therapy for children with type 1 diabetes. Due to physiological differences they have other requirements for their insulin pump than adults. The main difference is the need for very low basal rates. Even though most available insulin pumps reach a high accuracy at usual basal rates, accuracy decreases for lower rates. In addition, the lowest delivered amount at 1 time is limiting the fine tuning of the basal rate as well as the option for temporary basal rates. Alarms in case of occlusions depend on accumulation of a certain amount of insulin in the catheter, and therefore the time until such an alarm is triggered is much longer with lower basal rates. Accordingly, the risk for hyperglycemia developing into diabetic ketoacidosis increases. The availability of bolus advisors facilitates the calculation of meal and correction boluses for children and their parents. However, there are some differences between the calculators, and the settings that the calculation is based on are very important. Better connectivity, for example with a system for continuous glucose monitoring, might help to further increase safety in the use of CSII in children. When selecting an insulin pump for a child, the features and characteristics of available pumps should be properly compared to ensure an effective and safe therapy.Keywords
Funding Information
- Roche Diabetes Care GmbH, Germany
- Accu-Chek
This publication has 26 references indexed in Scilit:
- The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: a randomised controlled trialDiabetologia, 2012
- Carbohydrate counting with a bolus calculator improves post-prandial blood glucose levels in children and adolescents with type 1 diabetes using insulin pumpsPediatric Diabetes, 2012
- Development of Optimal Kids Insulin Dosing System Formulas for Young Children with Type 1 Diabetes MellitusDiabetes Technology & Therapeutics, 2012
- Significant Time Until Catheter Occlusion Alerts in Currently Marketed Insulin Pumps at Two Basal RatesDiabetes Technology & Therapeutics, 2012
- Prevention of Hypoglycemia by Using Low Glucose Suspend Function in Sensor-Augmented Pump TherapyDiabetes Technology & Therapeutics, 2011
- Basal rates and circadian profiles in continuous subcutaneous insulin infusion (CSII) differ for preschool children, prepubertal children, adolescents and young adultsPediatric Diabetes, 2011
- Bolus Calculator: A Review of Four “Smart” Insulin PumpsDiabetes Technology & Therapeutics, 2008
- Establishing glycaemic control with continuous subcutaneous insulin infusion in children and adolescents with type 1 diabetes: experience of the PedPump Study in 17 countriesDiabetologia, 2008
- Use of Insulin Pump Therapy in the Pediatric Age-GroupDiabetes Care, 2007
- Hypoglycemia and ketoacidosis with insulin pump therapy in children and adolescentsPediatric Diabetes, 2006