Evaluating the interaction of a tracheobronchial stent in an ovine in-vivo model
- 24 November 2017
- journal article
- research article
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 17 (2) , 499-516
Abstract
Tracheobronchial stents are used to restore patency to stenosed airways. However, these devices are associated with many complications such as stent migration, granulation tissue formation, mucous plugging and stent strut fracture. Of these, granulation tissue formation is the complication that most frequently requires costly secondary interventions. In this study a biomechanical lung modelling framework recently developed by the authors to capture the lung in-vivo stress state under physiological loading is employed in conjunction with ovine pre-clinical stenting results and device experimental data to evaluate the effect of stent interaction on granulation tissue formation. Stenting is simulated using a validated model of a prototype covered laser-cut tracheobronchial stent in a semi-specific biomechanical lung model, and physiological loading is performed. Two computational methods are then used to predict possible granulation tissue formation: the standard method which utilises the increase in maximum principal stress change, and a newly proposed method which compares the change in contact pressure over a respiratory cycle. These computational predictions of granulation tissue formation are then compared to pre-clinical stenting observations after a 6-week implantation period. Experimental results of the pre-clinical stent implantation showed signs of granulation tissue formation both proximally and distally, with a greater proximal reaction. The standard method failed to show a correlation with the experimental results. However, the contact change method showed an apparent correlation with granulation tissue formation. These results suggest that this new method could be used as a tool to improve future device designs.Keywords
This publication has 61 references indexed in Scilit:
- Studying the effects of chain extenders chemical structures on the adhesion and mechanical properties of a polyurethane adhesiveJournal of Industrial and Engineering Chemistry, 2013
- Filling the void: A coalescent numerical and experimental technique to determine aortic stent graft mechanicsJournal of Biomechanics, 2013
- A computational method to assess the in vivo stresses and unloaded configuration of patient-specific blood vesselsJournal of Computational and Applied Mathematics, 2013
- FE simulation of human trachea swallowing movement before and after the implantation of an endoprothesisApplied Mathematical Modelling, 2011
- Toward efficient biomechanical-based deformable image registration of lungs for image-guided radiotherapyPhysics in Medicine & Biology, 2011
- FSI Analysis of a Human Trachea Before and After Prosthesis ImplantationJournal of Biomechanical Engineering, 2011
- An outcome analysis of self-expandable metallic stents in central airway obstruction: a cohort studyJournal of Cardiothoracic Surgery, 2011
- Results of a Multi-Institution Deformable Registration Accuracy Study (MIDRAS)International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Supine and prone differences in regional lung density and pleural pressure gradients in the human lung with constant shapeJournal of Applied Physiology, 2009
- Airway StentingSurgery Today, 2005