Quantification of left and right atrial kinetic energy using four-dimensional intracardiac magnetic resonance imaging flow measurements
Authors:
Open Access
- 15 May 2013
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 114 (10) , 1472-1481
Abstract
Kinetic energy (KE) of atrial blood has been postulated as a possible contributor to ventricular filling. Therefore, we aimed to quantify the left (LA) and right (RA) atrial blood KE using cardiac magnetic resonance (CMR). Fifteen healthy volunteers underwent CMR at 3 T, including a four-dimensional phase-contrast flow sequence. Mean LA KE was lower than RA KE (1.1 ± 0.1 vs. 1.7 ± 0.1 mJ, P < 0.01). Three KE peaks were seen in both atria: one in ventricular systole, one during early ventricular diastole, and one during atrial contraction. The systolic LA peak was significantly smaller than the RA peak ( P < 0.001), and the early diastolic LA peak was larger than the RA peak ( P < 0.05). Rotational flow contained 46 ± 7% of total KE and conserved energy better than nonrotational flow did. The KE increase in early diastole was higher in the LA ( P < 0.001). Systolic KE correlated with the combination of atrial volume and systolic velocity of the atrioventricular plane displacement ( r2 = 0.57 for LA and r2 = 0.64 for RA). Early diastolic KE of the LA correlated with left ventricle (LV) mass ( r2 = 0.28), however, no such correlation was found in the right heart. This suggests that LA KE increases during early ventricular diastole due to LV elastic recoil, indicating that LV filling is dependent on diastolic suction. Right ventricle (RV) relaxation does not seem to contribute to atrial KE. Instead, RA KE generated during ventricular systole may be conserved in a hydraulic “flywheel” and transferred to the RV through helical flow, which may contribute to RV filling.Keywords
This publication has 39 references indexed in Scilit:
- Quantification of left and right ventricular kinetic energy using four-dimensional intracardiac magnetic resonance imaging flow measurementsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2012
- 4-D blood flow in the human right ventricleAmerican Journal of Physiology-Heart and Circulatory Physiology, 2011
- Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: head to head comparison and validation at 1.5 T and 3 TJournal of Cardiovascular Magnetic Resonance, 2011
- Relation between cardiac dimensions and peak oxygen uptakeJournal of Cardiovascular Magnetic Resonance, 2010
- Peak oxygen uptake in relation to total heart volume discriminates heart failure patients from healthy volunteers and athletesJournal of Cardiovascular Magnetic Resonance, 2010
- Letter to the editor: “Postulated functional advantages of a looped as opposed to a linearly arranged heart”American Journal of Physiology-Heart and Circulatory Physiology, 2010
- Reply to “Letter to the editor: ‘Postulated functional advantages of a looped as opposed to a linearly arranged heart’”American Journal of Physiology-Heart and Circulatory Physiology, 2010
- Design and validation of Segment - freely available software for cardiovascular image analysisBMC Medical Imaging, 2010
- Assessment of left atrial volumes and phasic function using cine magnetic resonance imaging in normal subjectsThe American Journal of Cardiology, 1994
- The reservoir function of the left atrium during ventricular systoleThe American Journal of Medicine, 1964