OCT for Efficient High Quality Laser Welding
Open Access
- 12 May 2016
- journal article
- process monitoring
- Published by Wiley in PhotonicsViews
- Vol. 13 (3) , 37-41
Abstract
High requirements for duration and quality of laser welding are the main topics in the line production nowadays, especially in the automotive industry. With acquisition rates up to 100 kHz and microseconds duration capture times, optical coherence tomography (OCT) is a powerful adaptive tool, with a few microns resolution, for real‐time direct non‐contact investigation of material processing. The measurement system used to acquire the workpiece topography enables high accuracy automatic seam tracking, process monitoring and quality assurance (QA), and these functions are executed simultaneously.Keywords
This publication has 2 references indexed in Scilit:
- Real time monitoring of laser beam welding keyhole depth by laser interferometryScience and Technology of Welding and Joining, 2014