Paper based point of care immunosensor for the impedimetric detection of cardiac troponin I biomarker
- 16 December 2019
- journal article
- research article
- Published by Springer Nature in Biomedical Microdevices
- Vol. 22 (1) , 6
Abstract
Advancements in health care monitoring demand a rapid, accurate and reliable early diagnosis of “Heart Attack” (acute myocardial infarction) with an objective to develop a cost-effective, rapid and label-free point of care diagnostic test kit for the detection of cardiac troponin I (cTnI) on paper-based multi-frequency impedimetric transducers. Paper based sensing platforms were developed by integrating carboxyl group functionalized multi-walled carbon nanotubes (MWCNT) with antibodies of cardiac troponin I (anti-cTnI) biomarker and was characterized using Electrochemical Impedance Spectroscopy (EIS). Various concentrations of cTnI with anti cTnI were studied as a function of impedance change. The suitability of the proposed immunosensor is demonstrated by spiking cTnI in blood serum samples. The limit of detection (LoD) and sensitivity of the proposed sensor was determined to be 0.05 ng/mL and 1.85 mΩ/ng/mL respectively, with a response time of ~1 min. The shelf life of the fabricated sensor was nearly 30 days. The rapid response, very low detection limit, and cost effectiveness offer a portable platform to detect cTnI in blood serum samples. The proposed immunosensor, therefore, offers an affordable healthcare diagnostic platform in resource limited areas.Keywords
This publication has 47 references indexed in Scilit:
- Portable bioactive paper based genosensor incorporated with Zn-Ag nanoblooms for herpes detection at the point-of-careInternational Journal of Biological Macromolecules, 2018
- Detection of alprazolam with a lab on paper economical device integrated with urchin like Ag@ Pd shell nano-hybridsMaterials Science and Engineering: C, 2017
- Lab on paper chip integrated with Si@GNRs for electroanalysis of diazepamAnalytica Chimica Acta, 2017
- Point of care with micro fluidic paper based device integrated with nano zeolite–graphene oxide nanoflakes for electrochemical sensing of ketamineBiosensors and Bioelectronics, 2017
- Cardiovascular disease detection using bio-sensing techniquesTalanta, 2014
- Simple Telemedicine for Developing Regions: Camera Phones and Paper-Based Microfluidic Devices for Real-Time, Off-Site DiagnosisAnalytical Chemistry, 2008
- Lab-on-a-chip devices for global health: Past studies and future opportunitiesLab on a Chip, 2006
- Biomarkers of Cardiovascular DiseaseCirculation, 2006
- Diagnostics for the developing worldNature Reviews Microbiology, 2004
- An Integrated Approach to a Portable and Low‐Cost Immunoassay for Resource‐Poor SettingsAngewandte Chemie International Edition, 2004