Measurement of Exhaled Nitric Oxide in a General Population Sample: A Comparison of the Medisoft HypAir FENOand Aerocrine NIOX Analyzers
Authors:
- Collin R. BrooksCBCollin R. Brooks
- Shirley-Belle M. BroganSBShirley-Belle M. Brogan
- Christine J. van DalenCDChristine J. van Dalen
- Phillipa K. LampshirePLPhillipa K. Lampshire
- Julian CraneJCJulian Crane
- Jeroen DouwesJDJeroen Douwes
- 9 March 2011
- journal article
- research article
- Published by Taylor & Francis in Journal of Asthma
- Vol. 48 (4) , 324-328
Abstract
Background and objective. Measuring the fraction of nitric oxide in exhaled breath (FENO) is increasingly utilized to assess airway inflammation in asthma. The primary aim of this study was to compare exhaled nitric oxide measurements obtained using two devices from different manufacturers, that is, the recently marketed portable and electrochemical-based Medisoft HypAir FENO and the well-established chemiluminescence-based Aerocrine NIOX analyzer, in an unselected population. Methods. FENO measurements were conducted in 106 subjects (86 healthy; 20 asthmatic; 56.6% atopic). Atopy and health status were assessed by skin prick tests and questionnaire, respectively. Results. The two instruments showed strong correlation over a wide range of FENO measurements (8–261.3 ppb with the HypAir, 5.6–156.8 ppb with the NIOX; r = 0.98; p < .0001). This correlation was observed in the population as a whole, as well as in healthy non-atopics, healthy atopics, and atopic asthmatics when considered separately. The measurements on the HypAir FENO were consistently 1.6 times (95% CI 1.11–2.05) higher than those obtained with the NIOX. Conclusions. FENO measurements obtained with the HypAir FENO correlated well with the NIOX, but were approximately 1.6 times higher. Therefore, a conversion factor is required if results are to be compared with the NIOX instrument.Keywords
This publication has 19 references indexed in Scilit:
- Measurement of exhaled nitric oxide: Comparison of different analysersRespirology, 2010
- Measurement of Fractional Exhaled Nitric Oxide by a New Portable Device: Comparison with the Standard TechniqueJournal of Asthma, 2010
- Comparability of a hand‐held nitric oxide analyser with online and offline chemiluminescence‐based nitric oxide measurementPediatric Allergy and Immunology, 2009
- Exhaled nitric oxide measurements: Correction equation to compare hand-held device to stationary analyzerRespiratory Medicine, 2008
- Exhaled nitric oxide: Independent effects of atopy, smoking, respiratory tract infection, gender and heightRespiratory Medicine, 2008
- Factors affecting exhaled nitric oxide measurements: the effect of sexRespiratory Research, 2007
- A comparison of exhaled nitric oxide measurements performed using three different analysersRespiratory Medicine, 2006
- The use of exhaled nitric oxide concentration to identify eosinophilic airway inflammation: an observational study in adults with asthmaClinical & Experimental Allergy, 2005
- The Aerocrine exhaled nitric oxide monitoring system NIOX is cleared by the US Food and Drug Administration for monitoring therapy in asthmaJournal of Allergy and Clinical Immunology, 2004
- Correlation between exhaled nitric oxide, sputum eosinophils, and methacholine responsiveness in patients with mild asthma.Thorax, 1998