Bacterial contamination of suction catheter tips during aortic valve replacement surgery: a prospective observational cohort study
Open Access
- 14 May 2015
- journal article
- research article
- Published by Springer Nature in Patient Safety in Surgery
- Vol. 9 (1) , 1-5
Abstract
Bacterial mediastinitis is a severe complication after open heart surgery. The infection causes prolonged hospitalization and an increased mortality risk. Observations from orthopaedic surgery showed that the suction catheter used during surgery is commonly contaminated with bacteria. The aim of this study was to describe the prevalence of suction catheter contamination in cardiac surgery and to study if suction time influences the contamination risk. Fifty suction catheter tips were collected during 25 aortic valve replacement operations. The suction tip was exchanged once during the operation (after aortotomy closure). The tips were subjected to bacterial contamination analysis. In 20 of the 25 investigated cases (80%), bacterial contamination was detected on one or both tips. The tip used during the beginning of the operation showed bacterial contamination in 13/25 cases (52%) and the second tip in 12/25 (48%). In 5/25 cases (20%) both tips were contaminated. There was no association between bacterial contamination and suction time. Coagulase-negative staphylococcus was the most commonly detected microorganism. The suction device should be considered as a potential source of bacterial contamination in cardiac surgery. The results suggest that the suction catheter should be replaced before key moments like valve implantation and sternal closure.Keywords
This publication has 18 references indexed in Scilit:
- Bacterial recolonization of the skin and wound contamination during cardiac surgery: a randomized controlled trial of the use of plastic adhesive drape compared with bare skinJournal of Hospital Infection, 2013
- Surgical site infections: epidemiology, microbiology and preventionJournal of Hospital Infection, 2008
- Suction during orthopaedic surgery. How safe is the suction tip?2008
- Wound contamination in cardiac surgeryAPMIS, 2007
- Cost Analysis of Surgical Site InfectionsSurgical Infections, 2006
- Surgical site infection – a European perspective of incidence and economic burdenInternational Wound Journal, 2004
- Postoperative mediastinitis in cardiac surgery — microbiology and pathogenesisEuropean Journal of Cardio-Thoracic Surgery, 2002
- Coagulase-Negative Staphylococcal Sternal Wound Infections After Open Heart OperationsThe Annals of Thoracic Surgery, 1997
- Postoperative mediastinitis: Classification and managementThe Annals of Thoracic Surgery, 1996
- Bacteriologic contamination of suction tips during hip arthroplastyActa Orthopaedica, 1988