Evaluation of Pipeline Flex delivery system for the treatment of unruptured aneurysms
Authors:
- 20 September 2016
- journal article
- research article
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 13 (10) , 885-897
Abstract
Refinements in endovascular technology have revolutionized the treatment of intracranial aneurysms (IAs) with the development of flow-diversion technology. The first generation of the Pipelin Embolization Device (PED) has demonstrated its safety and efficacy. However, the deployment technique was a difficult task that often led to complex maneuvers. The Pipeline Flex Embolization Device (PED Flex) is the second generation and its introduction has arrived with high expectations due to a completely redesigned delivery system that intends to overcome deployment difficulties seen in the previous generation. Areas covered: Preclinical studies, mechanism of action of flow-diverters, technical aspects and deployment system of the PED Flex, and clinical outcomes with both PED generations. Expert commentary: Flow diversion has allowed us to treat lesions that would be otherwise challenging for surgical clipping or unsuitable for other endosaccular strategies. Although the experience with PED Flex is limited, initial results suggest its safety and short-term efficacy.Keywords
This publication has 102 references indexed in Scilit:
- Endovascular Treatment of Intracranial Aneurysms With Flow DivertersStroke, 2013
- Pipeline™ Embolization Device for the Treatment of Complex Intracranial AneurysmsApplied Health Economics and Health Policy, 2013
- Guidelines for the Management of Aneurysmal Subarachnoid HemorrhageStroke, 2012
- Flow Diverters at and Beyond the Level of the Circle of Willis for the Treatment of Intracranial AneurysmsStroke, 2012
- Cerecyte Coil Trial: Procedural Safety and Clinical Outcomes in Patients with Ruptured and Unruptured Intracranial AneurysmsAmerican Journal of Neuroradiology, 2011
- Neuroform Stent−Assisted Coiling of Unruptured Intracranial Aneurysms: Short- and Midterm Results from a Single-Center Experience with 68 PatientsAmerican Journal of Neuroradiology, 2010
- Flow-Diverter Stent for the Endovascular Treatment of Intracranial AneurysmsStroke, 2010
- Curative cerebrovascular reconstruction with the Pipeline embolization device: the emergence of definitive endovascular therapy for intracranial aneurysmsJournal of NeuroInterventional Surgery, 2009
- An Original Flow Diversion Device for the Treatment of Intracranial AneurysmsStroke, 2009
- Long-Term Angiographic Recurrences After Selective Endovascular Treatment of Aneurysms With Detachable CoilsStroke, 2003