Near-Infrared Spectroscopy for the In Vivo Monitoring of Biodegradable Implants in Rats
Open Access
Abstract
Magnesium (Mg) alloys possess unique properties that make them ideal for use as biodegradable implants in clinical applications. However, reports on the in vivo assessment of these alloys are insufficient. Thus, monitoring the degradation of Mg and its alloys in vivo is challenging due to the dynamic process of implant degradation and tissue regeneration. Most current works focus on structural remodeling, but functional assessment is crucial in providing information about physiological changes in tissues, which can be used as an early indicator of healing. Here, we report continuous wave near-infrared spectroscopy (CW NIRS), a non-invasive technique that is potentially helpful in assessing the implant–tissue dynamic interface in a rodent model. The purpose of this study was to investigate the effects on hemoglobin changes and tissue oxygen saturation (StO2) after the implantation of Mg-alloy (WE43) and titanium (Ti) implants in rats’ femurs using a multiwavelength optical probe. Additionally, the effect of changes in the skin on these parameters was evaluated. Lastly, combining NIRS with photoacoustic (PA) imaging provides a more reliable assessment of tissue parameters, which is further correlated with principal component analysis.Keywords
Funding Information
- European Commission (811226)
This publication has 48 references indexed in Scilit:
- In vivo behavior of biodegradable Mg–Nd–Y–Zr–Ca alloyJournal of Materials Science: Materials in Medicine, 2011
- Magnesium hydroxide temporarily enhancing osteoblast activity and decreasing the osteoclast number in peri-implant bone remodelling☆Acta Biomaterialia, 2010
- Monitoring trauma and intensive care unit resuscitation with tissue hemoglobin oxygen saturationCritical Care, 2009
- Noninvasive in Vivo Measurement of Venous Blood pH during Exercise Using Near-Infrared Reflectance SpectroscopyApplied Spectroscopy, 2007
- Optical Properties of Wounds: Diabetic Versus Healthy TissueIEEE Transactions on Biomedical Engineering, 2006
- In vivo corrosion of four magnesium alloys and the associated bone responseBiomaterials, 2005
- Skin Blood Flow Affects In Vivo Near-Infrared Spectroscopy Measurements in Human Skeletal MuscleThe Japanese Journal of Physiology, 2005
- Statistics of Penetration Depth of Photons Re-emitted from Irradiated TissueJournal of Modern Optics, 1989
- Estimation of optical pathlength through tissue from direct time of flight measurementPhysics in Medicine & Biology, 1988
- The Use of Principal Components in the Analysis of Near-Infrared SpectraApplied Spectroscopy, 1985