Chronic stability of a neuroprosthesis comprising multiple adjacent Utah arrays in monkeys
Open Access
- 1 June 2023
- journal article
- research article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (3) , 036039
Abstract
Objective. Electrical stimulation of visual cortex via a neuroprosthesis induces the perception of dots of light (‘phosphenes’), potentially allowing recognition of simple shapes even after decades of blindness. However, restoration of functional vision requires large numbers of electrodes, and chronic, clinical implantation of intracortical electrodes in the visual cortex has only been achieved using devices of up to 96 channels. We evaluated the efficacy and stability of a 1024-channel neuroprosthesis system in non-human primates (NHPs) over more than 3 years to assess its suitability for long-term vision restoration. Approach. We implanted 16 microelectrode arrays (Utah arrays) consisting of 8 × 8 electrodes with iridium oxide tips in the primary visual cortex (V1) and visual area 4 (V4) of two sighted macaques. We monitored the animals’ health and measured electrode impedances and neuronal signal quality by calculating signal-to-noise ratios of visually driven neuronal activity, peak-to-peak voltages of the waveforms of action potentials, and the number of channels with high-amplitude signals. We delivered cortical microstimulation and determined the minimum current that could be perceived, monitoring the number of channels that successfully yielded phosphenes. We also examined the influence of the implant on a visual task after 2–3 years of implantation and determined the integrity of the brain tissue with a histological analysis 3–3.5 years post-implantation. Main results. The monkeys remained healthy throughout the implantation period and the device retained its mechanical integrity and electrical conductivity. However, we observed decreasing signal quality with time, declining numbers of phosphene-evoking electrodes, decreases in electrode impedances, and impaired performance on a visual task at visual field locations corresponding to implanted cortical regions. Current thresholds increased with time in one of the two animals. The histological analysis revealed encapsulation of arrays and cortical degeneration. Scanning electron microscopy on one array revealed degradation of IrOx coating and higher impedances for electrodes with broken tips. Significance. Long-term implantation of a high-channel-count device in NHP visual cortex was accompanied by deformation of cortical tissue and decreased stimulation efficacy and signal quality over time. We conclude that improvements in device biocompatibility and/or refinement of implantation techniques are needed before future clinical use is feasible.Keywords
Funding Information
- NWO (17619)
- DFG (EXC 1086)
- Human Brain Project (650003)
- ERC (101052963)
This publication has 84 references indexed in Scilit:
- Visual Acuity of Simulated Thalamic Visual Prostheses in Normally Sighted HumansPLOS ONE, 2013
- Collaborative Approach in the Development of High‐Performance Brain–Computer Interfaces for a Neuroprosthetic Arm: Translation from Animal Models to Human ControlClinical and Translational Science, 2013
- Reach and grasp by people with tetraplegia using a neurally controlled robotic armNature, 2012
- Multiple factors may influence the performance of a visual prosthesis based on intracortical microstimulation: nonhuman primate behavioural experimentationJournal of Neural Engineering, 2011
- Microstimulation Reveals Limits in Detecting Different Signals from a Local Cortical RegionCurrent Biology, 2010
- Perceiving electrical stimulation of identified human visual areasProceedings of the National Academy of Sciences, 2009
- Depth‐dependent detection of microampere currents delivered to monkey V1European Journal of Neuroscience, 2009
- Electrical microstimulation thresholds for behavioral detection and saccades in monkey frontal eye fieldsProceedings of the National Academy of Sciences, 2008
- The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skullJournal of Biomedical Materials Research Part A, 2007
- Behavioral Detection of Electrical Microstimulation in Different Cortical Visual AreasCurrent Biology, 2007