A Monte Carlo Sensitivity Analysis for a Dimensionally Reduced-Order Model of the Aortic Dissection
- 21 February 2024
- journal article
- research article
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 15 (3) , 333-345
Abstract
Purpose Aortic dissection is associated with a high mortality rate. Although computational approaches have shed light on many aspects of the disease, a sensitivity analysis is required to determine the significance of different factors. Because of its complex geometry and high computational expense, the three-dimensional (3D) fluid-structure interaction (FSI) simulation is not a suitable approach for sensitivity analysis. Methods We performed a Monte Carlo simulation (MCS) to investigate the sensitivity of hemodynamic quantities to the lumped parameters of our zero-dimensional (0D) model with numerically calculated lumped parameters. We performed local and global analyses on the effect of the model parameters on important hemodynamic quantities. Results The MCS showed that a larger lumped resistance value for the false lumen and the tears result in a higher retrograde flow rate in the false lumen (the coefficient of variation, \({c}_{{\text{v}},i}=0.0183\), the sensitivity \({S}_{{{\text{X}}}_{i}}^{\sigma }= 0.54\), Spearman’s coefficient,\({\rho }_{{\text{s}}}=0.464\)). For the intraluminal pressure, our results show a significant role in the resistance and inertance of the true lumen (the coefficient of variation, \({c}_{{\text{v}},i}=0.0640\), the sensitivity \({S}_{{{\text{X}}}_{i}}^{\sigma }= 0.85\), and Spearman’s coefficient,\({\rho }_{{\text{s}}}=0.855\) for the inertance of the true lumen). Conclusion This study highlights the necessity of comparing the results of the local and global sensitivity analyses to understand the significance of multiple lumped parameters. Because of the efficiency of the method, our approach is potentially useful to investigate and analyze medical planning.
Keywords
This publication has 37 references indexed in Scilit:
- Aortic dissection simulation models for clinical support: fluid-structure interaction vs. rigid wall modelsBioMedical Engineering OnLine, 2015
- Spearman’s rank correlation coefficientBMJ, 2014
- 2014 ESC Guidelines on the diagnosis and treatment of aortic diseasesEuropean Heart Journal, 2014
- Endovascular Repair of Type B Aortic DissectionCirculation: Cardiovascular Interventions, 2013
- Four-dimensional, flow-sensitive magnetic resonance imaging of blood flow patterns in thoracic aortic dissectionsThe Journal of Thoracic and Cardiovascular Surgery, 2013
- A new method for quantification of false lumen thrombosis in aortic dissection using magnetic resonance imaging and a blood pool contrast agentJournal of Vascular Surgery, 2011
- A microRNA profile comparison between thoracic aortic dissection and normal thoracic aorta indicates the potential role of microRNAs in contributing to thoracic aortic dissection pathogenesisJournal of Vascular Surgery, 2011
- Review of Zero-D and 1-D Models of Blood Flow in the Cardiovascular SystemBioMedical Engineering OnLine, 2011
- Aortic dimensions and the risk of dissectionHeart, 2005
- Numerical Simulation and Experimental Validation of Blood Flow in Arteries with Structured-Tree Outflow ConditionsAnnals of Biomedical Engineering, 2000