Evaluation of Efficacy of a New Cryoprobe for Transbronchial Cryobiopsy: A Randomized, Controlled in vivo Animal Study
- 26 February 2020
- journal article
- research article
- Published by S. Karger AG in Respiration
- Vol. 99 (3) , 248-256
Abstract
Background: Forceps biopsy (FB) is still the most popular procedure for the bronchoscopic sampling of lung tissue. However, it has limitations like inadequate sample size and crush artifacts. Cryobiopsy (CB) has been introduced to obtain bronchoscopic biopsies with improved diagnostic yield compared to FB. Limitations of CB are the need to retract the cryoprobe en bloc with bronchoscope because samples are larger than the working channel and the variations of the freezing power of the reusable CB (rCB). Therefore, 3 new disposable cryoprobes (dCB) have been developed with different outer diameters: 1.1 mm (CB11-S) that can be retracted through the working channel of the bronchoscope, 1.7 mm (CB17) and 2.4 mm (CB24n), respectively. Objectives: The aim was to evaluate the new cryoprobes with regard to feasibility, specimen area, specimen quality and complications. Methods: We compared biopsy samples of the new probes with those obtained by FB and by rCB in an in vivo (porcine) model. A flexible bronchoscope was used to perform biopsy at 4 different locations at the upper and lower lobes of the right and left lung, respectively. The biopsies were taken under fluoroscopic control. The biopsy tool and activation times were allocated randomly. Altogether 204 biopsy procedures were performed. Results: The sample quality of the dCB was superior to that of FB (all p < 0.05) and not significantly different to the rCB sample quality. Mean specimen sample area of all CB was significantly larger compared to FB (p < 0.05). The sample area of the small cryoprobe (CB11-S) was significantly smaller compared to the other CB probes (p < 0.05). No severe bleedings occurred. Pneumothoraces were detected in 3 of the 7 pigs. Conclusion: We conclude that CB with the new single-use instruments are feasible and represent a viable option to improve the diagnostic accuracy of histopathological evaluation compared to FB.Keywords
This publication has 22 references indexed in Scilit:
- Recurrent Endobronchial Diffuse Large B-cell Lymphoma. Diagnosed by CryoprobeArchivos de Bronconeumología, 2013
- Transbronchial cryo‐biopsy in lung transplantation patients: First reportRespirology, 2013
- Cryoprobe Transbronchial Lung Biopsy in Patients After Lung TransplantationChest, 2013
- Role of Flexible Bronchoscopic Cryotechnology in Diagnosing Endobronchial MassesThe Annals of Thoracic Surgery, 2013
- Morphometrical analysis of transbronchial cryobiopsiesDiagnostic Pathology, 2011
- Cryoprobe biopsy increases the diagnostic yield in endobronchial tumor lesionsThe Journal of Thoracic and Cardiovascular Surgery, 2010
- Endobronchial cryobiopsy or forceps biopsy for lung cancer diagnosisAnnals of Thoracic Medicine, 2010
- Experimental Study on Biopsy Sampling Using New Flexible Cryoprobes: Influence of Activation Time, Probe Size, Tissue Consistency, and Contact Pressure of the Probe on the Size of the Biopsy SpecimenLung, 2009
- Transbronchial Cryobiopsy: A New Tool for Lung BiopsiesRespiration, 2009
- Fiberoptic Bronchoscopic Cryotherapy in the Management of Tracheobronchial ObstructionChest, 1996