Objectives: Investigate and control an increase in bloodstream infections (BSIs) in an outpatient hemodialysis center.Patients and Design: A retrospective cohort study was conducted for patients receiving dialysis at the center from February 2000 to April 2001. A case–control study compared microbiological data for all BSIs that occurred during the study period with those for BSIs that occurred during a baseline period Qanuary 1999 to January 2000). BSI rates before and after a 1-month intervention (May 2001) were assessed. A case was defined as a new BSI during the study period.Results: The outbreak was polymicrobial, with approximately 30 species. The baseline BSI rate was 0.7 per 100 patient-months. From February 2000 to April 2001, the BSI rate increased to 4.2 per 100 patient-months. Overall, 75% of the BSIs were associated with central venous catheters (CVCs), but CVC use did not fully explain the increase in BSIs. In January 2000, when the center changed ownership, prepackaged CVC dressing kits and biweekly infection control monitoring were discontinued. Beginning in May 2001, staff were educated on CVC care, chlorhexidine replaced povidone-iodine for cutaneous antisepsis, gauze replaced transparent dressings, antimicrobial ointments containing polyethylene glycol at CVC exit sites were discontinued, and patients with CVCs were educated on cutaneous hygiene. After the intervention period, by October 2001, rates decreased to less than 1 BSI per 100 patient-months.Conclusions: Proper cutaneous antisepsis and access site care is crucial in preventing BSIs in patients receiving hemodialysis. Infection control programs, staff and patient education, and use of optimal antisepsis agents or prepackaged kits are useful toward this end.Keywords
This publication has 19 references indexed in Scilit:
- Serratia liquefaciensBloodstream Infections from Contamination of Epoetin Alfa at a Hemodialysis CenterNew England Journal of Medicine, 2001
- Hospital-acquired infections among chronic hemodialysis patientsAmerican Journal of Kidney Diseases, 2000
- Hand Contamination with Hepatitis C Virus in Staff Looking after Hepatitis C-Positive Hemodialysis PatientsAmerican Journal of Nephrology, 2000
- Effect of the Ownership of Dialysis Facilities on Patients' Survival and Referral for TransplantationNew England Journal of Medicine, 1999
- National kidney foundation report on dialyzer reuseAmerican Journal of Kidney Diseases, 1997
- Transparent Polyurethane Film as an Intravenous Catheter DressingJAMA, 1992
- Brief Report: Clustered Bacteremias in a Hemodialysis Unit: Cross-Contamination of Blood Tubing from Ultrafiltrate WasteInfection Control & Hospital Epidemiology, 1992
- Prospective randomised trial of povidone-iodine, alcohol, and chlorhexidine for prevention of infection associated with central venous and arterial cathetersThe Lancet, 1991
- A Prospective, Randomized Study Comparing Transparent and Dry Gauze Dressings for Central Venous CathetersThe Journal of Infectious Diseases, 1989
- Reuse of HemodialyzersJAMA, 1988