Effects of an Impedance Threshold Device on Hemodynamics andRestoration of Spontaneous Circulation in Prolonged Porcine Ventricular Fibrillation
Authors:
- 1 January 2007
- journal article
- research article
- Published by Taylor & Francis in Prehospital Emergency Care
- Vol. 11 (2) , 179-185
Abstract
Background. An impedance threshold device (ITD) has been designed to enhance circulation during CPR by creating a negative intrathoracic pressure during the relaxation phase of chest compression. Hypothesis. We sought to determine the effects of the ITD on coronary perfusion pressure (CPP), return of spontaneous circulation (ROSC), andshort-term survival (20 minutes after ROSC). We hypothesized that the ITD would improve all 3 variables when compared to standard CPR. Methods. Using a case-control design nested within a randomized primary study, we compared CPR with the ITD (ITD-CPR) to standard CPR without the device (S-CPR). We systematically assigned 36 domestic swine, weighing 23–29 kg, (18 per group) to resuscitation with either ITD-CPR or S-CPR after 8 minutes of untreated ventricular fibrillation (VF). At minute 8, mechanical chest compression andventilation began, anddrugs (0.1 mg/kg epinephrine, 40U vasopressin, 1.0 mg propranolol, 1 mEq/kg sodium bicarbonate) were given. The first rescue shock (150J biphasic) was delivered at minute 11 of VF. We recorded CPP, ROSC (systolic pressure > 80 mmHg sustained for 60 s continuously), andsurvival. Data were analyzed with Fisher's exact test andgeneralized estimating equations (GEE), with alpha = 0.05. Results. We analyzed 3,150 compressions. CPP for the ITD-CPR group (28.1 mmHg [95% CI 27–29.3 mmHg]), did not differ from the S-CPR group (32.3 mmHg [95% CI 31.2–33.4 mmHg]). ROSC occurred in 6/18 (33%) animals in the ITD-CPR, and14/18 (78%) in the S-CPR group (p = 0.02). Survival occurred in 3/18 (17%) ITD-CPR and13/18 (72%) S-CPR group (p = 0.003). Conclusions. ITD-CPR did not improve CPP compared to S-CPR. ROSC andsurvival were significantly lower with ITD-CPR.Keywords
This publication has 15 references indexed in Scilit:
- Clinical and hemodynamic comparison of 15:2 and 30:2 compression-to-ventilation ratios for cardiopulmonary resuscitation*Critical Care Medicine, 2006
- Use of an impedance threshold device improves short-term outcomes following out-of-hospital cardiac arrestResuscitation, 2005
- Effect of an inspiratory impedance threshold device on hemodynamics during conventional manual cardiopulmonary resuscitationResuscitation, 2005
- Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest*Critical Care Medicine, 2005
- Ventricular Fibrillation Scaling Exponent Can Guide Timing of Defibrillation and Other TherapiesCirculation, 2004
- Immediate defibrillation versus interventions first in a swine model of prolonged ventricular fibrillationResuscitation, 2003
- Inspiratory impedance threshold valve during CPRResuscitation, 2002
- Inspiratory Impedance During Active Compression-Decompression Cardiopulmonary ResuscitationCirculation, 2000
- C OMBINATION P HARMACOTHERAPY WITH D ELAYED C OUNTERSHOCK VS S TANDARD A DVANCED C ARDIAC L IFE S UPPORT A FTER P ROLONGED V ENTRICULAR F IBRILLATIONPrehospital Emergency Care, 2000
- Improving Active Compression-Decompression Cardiopulmonary Resuscitation With an Inspiratory Impedance ValveCirculation, 1995