High‐performance liquid chromatographic method for determination of leucovorin in plasma: validation and application to a pharmacokinetic study in healthy volunteers
Authors:
- 20 March 2002
- journal article
- research article
- Published by Wiley in Biomedical Chromatography
- Vol. 16 (4) , 282-286
Abstract
A sensitive and reliable high‐performance liquid chromatographic (HPLC) method, using a solid‐phase extraction (SPE), was developed and validated for determination of leucovorin (LV) in human plasma. Plasma sample was extracted by using a Sep‐Pak cartridge which could be renewable. The sample was analyzed by HPLC with UV detection at 286 nm. The method was shown to perform selectively and sensitively for LV. The main metabolite of LV, 5‐methyltetrahydrofolic acid, and endogenous substances in plasma did not show any interference in the analysis. The limit of detection was 10 ng/mL for LV in plasma and the linear range was 50–1500 ng/mL in plasma. The relative standard deviation (RSD) of intra‐day and inter‐day assays was 2.8–6.1% and 2.4–5.3%, respectively. The extraction recoveries of LV in plasma were over 90%. The method was proved to be applicable to the pharmacokinetic study of LV in healthy volunteers after a single oral administration (75 mg). The pharmacokinetic parameters and relative bioavailability were investigated for domestic LV tablet and capsule vs an imported tablet. Copyright © 2002 John Wiley & Sons, Ltd.Keywords
This publication has 9 references indexed in Scilit:
- Pharmacokinetic and pharmacodynamic comparison of two doses of calcium folinate combined with continuous fluorouracil infusion in patients with advanced colorectal cancerInternational Journal of Clinical Pharmacy, 1999
- A comprehensive review of 5-fluorouracil and leucovorin in patients with metastatic colorectal carcinomaCancer, 1997
- Adjuvant chemotherapy in colorectal cancer with high-dose leucovorin and fluorouracil: impact on disease-free survival and overall survival.Journal of Clinical Oncology, 1997
- Highly sensitive coupled-column high-performance liquid chromatographic method for the separation and quantitation of the diastereomers of leucovorin and 5-methyltetrahydrofolate in serum and urineJournal of Chromatography B: Biomedical Sciences and Applications, 1995
- High-performance liquid chromatographic determination of methotrexate, 7-hydroxymethotrexate, 5-methyltetrahydrofolic acid and folinic acid in serum and cerebrospinal fluidJournal of Chromatography B: Biomedical Sciences and Applications, 1994
- Pharmacokinetics of rac‐leucovorin vs [S]‐leucovorin in patients with advanced gastrointestinal cancer.British Journal of Clinical Pharmacology, 1994
- HPLC of folinic acid diastereoisomers and 5-methyltetrahydrofolate in plasmaClinical Chemistry, 1993
- Determination of leucovorin and 5-fluorouracil in plasma by high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1993
- Optimization of the separation of (6R)- and (6S)- leucovorin and evaluation of the robustness of the optimumJournal of Chromatography A, 1992