An acoustically-driven biochip – impact of flow on the cell-association of targeted drug carriers
- 6 July 2009
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (19) , 2782-2788
Abstract
The interaction of targeted drug carriers with epithelial and endothelial barriers in vivo is largely determined by the dynamics of the body fluids. To simulate these conditions in binding assays, a fully biocompatible in vitro model was developed which can accurately mimic a wide range of physiological flow conditions on a thumbnail-format cell-chip. This acoustically-driven microfluidic system was used to study the interaction characteristics of protein-coated particles with cells. Poly(D,L-lactide-co-glycolide) (PLGA) microparticles (2.9 ± 1 µm) were conjugated with wheat germ agglutinin (WGA-MP, cytoadhesive protein) or bovine serum albumin (BSA-MP, non-specific protein) and their binding to epithelial cell monolayers was investigated under stationary and flow conditions. While mean numbers of 1500 ± 307 mm−2 WGA-MP and 94 ± 64 mm−2 BSA-MP respectively were detected to be cell-bound in the stationary setup, incubation at increasing flow velocities increasingly antagonized the attachment of both types of surface-modified particles. However, while binding of BSA-MP was totally inhibited by flow, grafting with WGA resulted in a pronounced anchoring effect. This was indicated by a mean number of 747 ± 241 mm−2 and 104 ± 44 mm−2 attached particles at shear rates of 0.2 s−1 and 1 s−1 respectively. Due to the compactness of the fluidic chip which favours parallelization, this setup represents a highly promising approach towards a screening platform for the performance of drug delivery vehicles under physiological flow conditions. In this regard, the flow-chip is expected to provide substantial information for the successful design and development of targeted micro- and nanoparticulate drug carrier systems.Keywords
All Related Versions
This publication has 29 references indexed in Scilit:
- Design maps for nanoparticles targeting the diseased microvasculatureBiomaterials, 2008
- Shear-induced unfolding triggers adhesion of von Willebrand factor fibersProceedings of the National Academy of Sciences, 2007
- DNA/cationic polymer complex attachment on a human vascular endothelial cell monolayer exposed to a steady laminar flowJournal of Controlled Release, 2006
- Microfluidics: Fluid physics at the nanoliter scaleReviews of Modern Physics, 2005
- Microfluidic System for Studying the Interaction of Nanoparticles and Microparticles with CellsAnalytical Chemistry, 2005
- Leukocyte-inspired biodegradable particles that selectively and avidly adhere to inflamed endothelium in vitro and in vivoProceedings of the National Academy of Sciences, 2003
- Microfluidic systems in proteomicsElectrophoresis, 2003
- Acoustically driven planar microfluidicsSuperlattices and Microstructures, 2003
- Receptor-mediated adhesion phenomena. Model studies with the Radical-Flow Detachment AssayBiophysical Journal, 1990
- Diagnosis of Urethral Flow Parameters by Ultrasonic BackscatterIEEE Transactions on Biomedical Engineering, 1975