Comparison of cardiac troponin assays reveals assay-specific sensitivities in a clinical model of very acute myocardial injury
Authors:
- Julius ObergasselJOJulius Obergassel
- Marc D LemoineMLMarc D Lemoine
- Laura C SommerfeldLSLaura C Sommerfeld
- Jan L RießJRJan L Rieß
- Laura RottnerLRLaura Rottner
- Andreas RilligARAndreas Rillig
- Andreas MetznerAMAndreas Metzner
- Nils A SörensenNSNils A Sörensen
- Larissa FabritzLFLarissa Fabritz
- Thomas RennéTRThomas Renné
- 25 April 2025
- journal article
- Published by Oxford University Press (OUP) in European Heart Journal: Acute Cardiovascular Care
- Vol. 14 (9) , 552-561
Abstract
Aims: High-sensitivity cardiac troponin (hs-cTn) assays indicating myocardial injury are critical for the diagnosis of acute myocardial infarction (AMI), but their use to differentiate between acute and chronic myocardial injury is limited. This study aimed to assess the differential utility of three hs-cTn assays, targeting different troponin epitopes (proximal and/or central), to detect myocardial injury in a clinical model of acute myocardial injury by left-atrial ablation. Methods and results: First, pre- and post-procedural serum samples were prospectively collected from 158 patients undergoing pulmonary vein isolation in a standardised setting. cTn-concentrations were measured using the high-sensitive Architect-cardiac troponin I (cTnI)-, Atellica-IM-cTnI-, and Elecsys-cTnT assays. Cardiac troponin I/T-concentrations and -ratios were compared, also to established AMI rule-in-thresholds. Second, 48 patients in which hs-cTn measurements were performed in clinical routine after ablation with a clinical indication were assessed for correlations between hs-cTn-levels, symptoms and electrocardiogram changes. The Atellica-assessed cTnI showed a doubled relative pre-to-post-procedural concentration increase compared to Architect-cTnI (39.6-fold vs. 20.5-fold; P = 0.0036). The Atellica-hs-cTnI/T-ratio had a 2.5 (95% confidence intervals (CI) 1.1,5.2) relative increase, while the Architect-cTnI-to-Elecsys-cTnT-ratio showed a 6.9 (95% CI 2.3,11.8) relative increase (P < 0.0001). In 78% of patients, at least one post-procedural cTn-concentration exceeded AMI rule-in-thresholds. Chronic kidney disease predicted higher pre-to-post-increases. In retrospectively analysed routine cTn-assessments after ablation, cTn-levels after ablation did not correlate with neither symptoms, electrocardiogram changes nor angiography findings. Conclusion: The Atellica assay demonstrated enhanced sensitivity for very acute myocardial injury, likely via its additional recognition of the proximally located cTnI epitope. This suggests its potential to improve differentiation of acute from chronic myocardial injury, warranting further investigation to confirm its clinical utility in that setting.Keywords
Funding Information
- Trust
- Deutsche Herzstiftung (F/02/22)
- Universität Hamburg (UHH/VP3/4/411.3)
- European Union MAESTRIA (965286)
- British Heart Foundation (AA/18/2/34218)
- Deutsches Zentrum für Herz-Kreislaufforschung
- German Ministry of Education and Research
- Deutsches Zentrum für Herz-Kreislaufforschung (DZHK FKZ 81X2800182, 81Z0710116, 81Z0710110)
- Deutsche Forschungsgemeinschaft (509167694)
- Fondation Leducq
This publication has 32 references indexed in Scilit:
- Diagnostic accuracy of a machine learning algorithm using point-of-care high-sensitivity cardiac troponin I for rapid rule-out of myocardial infarction: a retrospective studyThe Lancet Digital Health, 2024
- Comparison of Arctic Front Advance Pro and POLARx cryoballoons for ablation therapy of atrial fibrillation: an intraprocedural analysisClinical Research in Cardiology, 2024
- A novel platform allowing for pulsed field and radiofrequency ablation: First commercial atrial fibrillation ablation procedures worldwide with and without general anesthesiaHeart Rhythm, 2024
- Pericarditis After Catheter Ablation for Atrial FibrillationJACC: Clinical Electrophysiology, 2023
- Cardiac Troponin Assays to Distinguish Between Acute and Chronic Myocardial InjuryJACC, 2023
- Troponin release after pulmonary vein isolation using pulsed field ablation compared to radiofrequency and cryoballoon ablationHeart Rhythm, 2022
- High-sensitivity cardiac troponin and the diagnosis of myocardial infarction in patients with kidney impairmentKidney International, 2022
- High-Sensitivity Cardiac Troponin Assays Potentially Differentiate Acute From Chronic Myocardial InjuryJACC, 2019
- Early release of high-sensitive cardiac troponin during complex catheter ablation for ventricular tachycardia and atrial fibrillationJournal of Interventional Cardiac Electrophysiology, 2016
- Same-day cardiac catheter ablation is safe and cost-effective: Experience from a UK tertiary centerHeart Rhythm, 2015