Sensitivity of Spontaneous Baroreflex Control of the Heart and Hemodynamic Parameters are Not Influenced by the Menstrual Cycle
- 1 January 2006
- journal article
- research article
- Published by Taylor & Francis in Hypertension in Pregnancy
- Vol. 25 (3) , 159-167
Abstract
Objective: The purpose of this study was to evaluate if hemodynamic parameters and sympathetic activity vary between the follicular and luteal phase of the menstrual cycle before using sympathetic activity in pre-pregnancy risk assessment for preeclampsia. Methods: We studied 39 healthy women at days 5 to 10 and days 18 to 25 of the menstrual cycle. Blood pressure, heart rate, cardiac output, and total peripheral resistance were measured continuously using noninvasive finger arterial pressure waveform registration (Portapres Model 2, BMI, The Netherlands). Baroreflex sensitivity (BRS) and sympathetic activity by phase angle difference were studied using spectral analysis and xBRS. Results: There were no differences in hemodynamic parameters, BRS, and phase angle difference. Conclusion: There is no difference in blood pressure, BRS, and sympathetic activity between the first and second half of the menstrual period. We recommend using the first half of the cycle to be certain that no pregnancy exists, as the influence of very early pregnancy is unknown.Keywords
This publication has 30 references indexed in Scilit:
- Low Plasma Volume Coincides With Sympathetic Hyperactivity and Reduced Baroreflex Sensitivity In Formerly Preeclamptic PatientsJournal of the Society for Gynecologic Investigation, 2006
- Menstrual cycle and sex affect hemodynamic responses to combined orthostatic and heat stressAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- Pre-eclampsiaThe Lancet, 2005
- Assessing the Sensitivity of Spontaneous Baroreflex Control of the Heart: Deeper Insight Into Complex PhysiologyHypertension, 2004
- Serial assessment of cardiovascular control shows early signs of developing pre-eclampsiaJournal Of Hypertension, 2004
- Non–invasive assessment of autonomic cardiovascular control in normal human pregnancy and pregnancy- associated hypertensive disordersJournal Of Hypertension, 2002
- COMPARISON OF PORTAPRES® WITH STANDARD SPHYGMOMANOMETRY IN PREGNANCYHypertension in Pregnancy, 2002
- Continuous Cardiac Output in Septic Shock by Simulating a Model of the Aortic Input ImpedanceAnesthesiology, 1999
- Assessment of the Accuracy of Indirect Blood Pressure Measurements.Japanese Heart Journal, 1997
- Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.Hypertension, 1993