Effect of outlet impeller diameter on performance prediction of centrifugal pump under single-phase and cavitation flow conditions
- 29 November 2021
- journal article
- research article
- Published by Walter de Gruyter GmbH in International Journal of Nonlinear Sciences and Numerical Simulation
- Vol. 23 (7-8) , 1203-1229
Abstract
In this current study, the transient numerical calculations using CFD code are carried out under different outlet impeller diameters for the flow field within a centrifugal pump under single-phase and cavitation conditions. Both qualitative and quantitative analyses are carried out on all of these results in order to better understand the flow structure within a centrifugal pump. Also, the investigations using different outlet impeller diameters configurations relating to the static pressure, velocity magnitude, vapour volume fraction variations, as well as pressure fluctuations in both time and frequency domain at the impeller and volute of the pump are analysed. Velocity and static pressure variations of the pump under different outlet impeller diameters range (200, 210 and 220 mm) are investigated. Reliable model is developed and validated, at various pump operating conditions, to analyse the characteristics of pressure fluctuations in both time and frequency domain. Cavitation occurrence, under different outlet impeller diameters and flow rates, are detected and correlated, using a CFD model (volume fraction distributions). Based on the developed model’s findings, at the set operating conditions ranges, the distribution and impact (cavitation and head-wises) of both the pressure and velocity are analysed. The average pressure fluctuation in the volute for do = 210 mm is higher than for do = 200 mm by about 6.74%, also the maximum pressure fluctuation for do = 220 mm is higher than for do = 210 mm by around 7.4%. Furthermore, the maximum pressure fluctuation in the impeller for do = 210 mm is higher than for do = 200 mm by 12.48%, also for do = 220 mm is higher than for do = 210 mm by 10.8%. The developed CFD models are proved valuable tools in identifying and optimizing the pump performance and characterization. The head for when do = 220 mm is higher than for when do = 200 mm under both single-phase and cavitation conditions by around 14.13% and 14.69%. The maximum pressure fluctuation for do = 200 mm is lower than for do = 210 mm by 41.58%. Furthermore, the maximum pressure fluctuation at the impeller for do = 220 mm is higher than the two models. There is a small clearance between the impeller and the volute for this model, leading to the pressure fluctuation amplitudes being higher than the other above models.Keywords
This publication has 23 references indexed in Scilit:
- Dynamic mode decomposition of gas-liquid flow in a rotodynamic multiphase pumpRenewable Energy, 2019
- Influence of Geometry of Inlet Guide Vanes on Pressure Fluctuations of a Centrifugal PumpJournal of Fluids Engineering, 2018
- Numerical Prediction and Performance Experiment in an Engine Cooling Water Pump with Different Blade Outlet WidthsMathematical Problems in Engineering, 2017
- Investigation of Transient Flow in a Centrifugal Charging Pump during Charging Operating ProcessAdvances in Mechanical Engineering, 2014
- Numerical prediction and performance experiment in a deep-well centrifugal pump with different impeller outlet widthChinese Journal of Mechanical Engineering, 2013
- Design optimization of a centrifugal pump impeller and volute using computational fluid dynamicsIOP Conference Series: Earth and Environmental Science, 2012
- On the Capability of a RANS Method to Assess the Cavitation Erosion Risk on a Hydrofoil2012
- Numerical Studies on Effects of Blade Number Variations on Performance of Centrifugal Pumps at 4000 RPMInternational Journal of Engineering and Technology, 2011
- Avoiding wear in centrifugal pumps2003
- Relation between impact load and the damage produced by cavitation bubble collapseWear, 1995