Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry
Open Access
- 23 March 2004
- journal article
- research article
- Published by Springer Nature in BMC Ophthalmology
- Vol. 4 (1) , 4
Abstract
The new Ocular Dynamic Contour Tonometer (DCT), investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland) allows simultaneous recording of intraocular pressure (IOP) and ocular pulse amplitude (OPA). It was the aim of this study to compare the IOP results of this new device with Goldmann tonometry. Furthermore, IOP and OPA measured with the new slitlamp-mounted DCT were compared to the IOP and OPA measured with the hand-held SmartLens®, a gonioscopic contact lens tonometer (ODC Ophthalmic Development Company AG, Switzerland). Nineteen healthy subjects were included in this study. IOP was determined by three consecutive measurements with each of the DCT, SmartLens®, and Goldmann tonometer. Furthermore, OPA was measured three times consecutively by DCT and SmartLens®. No difference (P = 0.09) was found between the IOP values by means of DCT (mean: 16.6 mm Hg, median: 15.33 mm Hg, SD: +/- 4.04 mm Hg) and Goldmann tonometry (mean: 16.17 mm Hg, median: 15.33 mm Hg, SD: +/- 4.03 mm Hg). The IOP values of SmartLens® (mean: 20.25 mm Hg, median: 19.00 mm Hg, SD: +/- 4.96 mm Hg) were significantly higher (P = 0.0008) both from Goldmann tonometry and DCT. The OPA values of the DCT (mean: 3.08 mm Hg, SD: +/- 0.92 mm Hg) were significantly lower (P = 0.0003) than those obtained by SmartLens® (mean: 3.92 mm Hg, SD: +/- 0.83 mm Hg). DCT was equivalent to Goldmann applanation tonometry in measurement of IOP in a small group of normal subjects. In contrast, SmartLens® (contact lens tonometry) gave IOP readings that were significantly higher compared with Goldmann applanation tonometer readings. Both devices, DCT and SmartLens® provide the measurement of OPA which could be helpful e.g. for the management of glaucoma.Keywords
This publication has 24 references indexed in Scilit:
- Messung des Augeninnendrucks mit dem Tono-Pen im Vergleich zum Applanationstonometer nach Goldmann - eine klinische Studie an 100 AugenKlinische Monatsblätter für Augenheilkunde, 2002
- Ocular pulse amplitude is reduced in patients with advanced retinitis pigmentosaBritish Journal of Ophthalmology, 2001
- Reduktion der okulären Pulsamplitude unter Apraclonidin - prospektive doppelt maskierte Studie an 10 ProbandenKlinische Monatsblätter für Augenheilkunde, 2001
- Okuläre Pulsamplitude, intraokulärer Druck und Betablocker/Karboanhydrasehemmung in der Kombinationstherapie beim primären OffenwinkelglaukomKlinische Monatsblätter für Augenheilkunde, 1999
- Topical carbonic anhydrase inhibition increases ocular pulse amplitude in high tension primary open angle glaucomaBritish Journal of Ophthalmology, 1998
- Reduced ocular pulse amplitude in low tension glaucoma is independent of vasospasmEye, 1997
- Einfluß des Nifedipins auf die okuläre Pulsamplitude bei NormaldruckglaukomKlinische Monatsblätter für Augenheilkunde, 1997
- Comparison of the Tono-Pen to the Goldmann Applanation TonometerArchives of Ophthalmology (1950), 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESSActa Ophthalmologica, 1975