Effect of irradiation distance on image contrast in epi-optoacoustic imaging of human volunteers.
Open Access
- 1 October 2014
- journal article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 5 (11) , 3765-80
Abstract
In combined clinical optoacoustic (OA) and ultrasound (US) imaging, epi-mode irradiation and detection integrated into one single probe offers flexible imaging of the human body. The imaging depth in epi-illumination is, however, strongly affected by clutter. As shown in previous phantom experiments, the location of irradiation plays an important role in clutter generation. We investigated the influence of the irradiation geometry on the local image contrast of clinical images, by varying the separation distance between the irradiated area and the acoustic imaging plane of a linear ultrasound transducer in an automated scanning setup. The results for different volunteers show that the image contrast can be enhanced on average by 25% and locally by more than a factor of two, when the irradiated area is slightly separated from the probe. Our findings have an important impact on the design of future optoacoustic probes for clinical application.Keywords
This publication has 32 references indexed in Scilit:
- Biomedical photoacoustic imagingInterface Focus, 2011
- Real-time optoacoustic monitoring and three-dimensional mapping of a human arm vasculatureJournal of Biomedical Optics, 2010
- Photoacoustic imaging and characterization of the microvasculatureJournal of Biomedical Optics, 2010
- Coregistered three-dimensional ultrasound and photoacoustic imaging system for ovarian tissue characterizationJournal of Biomedical Optics, 2009
- Fast 3-D dark-field reflection-mode photoacoustic microscopy in vivo with a 30-MHz ultrasound linear arrayJournal of Biomedical Optics, 2008
- Refractive indices of human skin tissues at eight wavelengths and estimated dispersion relations between 300 and 1600 nmPhysics in Medicine & Biology, 2006
- Noninvasive imaging of hemoglobin concentration and oxygenation in the rat brain using high-resolution photoacoustic tomographyJournal of Biomedical Optics, 2006
- Transparent ITO coated PVDF transducer for optoacoustic depth profilingOptics Communications, 2005
- Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nmJournal of Biomedical Optics, 2001
- Effects of compression on soft tissue optical propertiesIEEE Journal of Selected Topics in Quantum Electronics, 1996