Imaging Simulation of a Dual-Panel PET Geometry With Ultrafast TOF Detectors
- 1 March 2026
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (3) , 418-426
Abstract
In positron emission tomography (PET), time-of-flight (TOF) information localizes source positions along lines of response. Cherenkov-radiator-integrated microchannel-plate photomultiplier tubes have achieved 30 ps TOF resolution, demonstrating cross-sectional imaging without reconstruction. Such ultrafast TOF detectors would free PET from conventional ring geometries. Therefore, this study aimed at investigating imaging characteristics of a dual-panel PET with ultrafast TOF detectors using Geant4 simulation. Two detector panels (137 W 137 mm2), which consisted of 5.0 mm-thick bismuth germanate pixelized crystals with a 5.75 mm pitch, were placed face-to-face at a 300 mm distance. Imaging characteristics with various TOF resolutions from 30 to 90 ps were evaluated. Because degraded efficiency may cancel TOF gain in image quality, detection efficiency was also parameterized by reducing coincidence counts. Data acquisitions for a numerical multi-rod and uniform phantom (21 MBq) and a modified NEMA NU2 image quality phantom were simulated for 600 s. Results of the maximum likelihood expectation maximization (MLEM) reconstruction were compared with those of a backprojection (i.e., no reconstruction). The dual-panel PET required a 40 ps TOF resolution to have a similar spatial resolution to that of a non-TOF ring PET (300 mm in diameter) for the same detection efficiency. TOF showed benefit in the reconstruction of image quality phantom with 40% efficiency, and the image noise with 20% efficiency at 30 ps TOF was similar to the complete efficiency at 40 ps TOF. MLEM provided better imaging performance than backprojection, even at 30 ps TOF. The feasibility of the proposed dual-panel PET was shown.Keywords
All Related Versions
Funding Information
- Japan Society for the Promotion of Science (JSPS) Kakenhi (20H05667)
- Nakatani Foundation
This publication has 42 references indexed in Scilit:
- Walk-through flat panel total-body PET: a patient-centered design for high throughput imaging at lower cost using DOI-capable high-resolution monolithic detectorsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2023
- A novel multi-anode MCP-PMT with Cherenkov radiator windowNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2023
- Ultrafast timing enables reconstruction-free positron emission imagingNature Photonics, 2021
- Scintillation Detectors for Charged Particles and Photons2020
- Novel method to measure the intrinsic spatial resolution in PET detectors based on monolithic crystalsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
- Online proton therapy monitoring: clinical test of a Silicon-photodetector-based in-beam PETScientific Reports, 2018
- Optical properties of bismuth germanateJournal of Applied Physics, 2010
- Design considerations for a limited angle, dedicated breast, TOF PET scannerPhysics in Medicine & Biology, 2008
- On the detector arrangement for in-beam PET for hadron therapy monitoringPhysics in Medicine & Biology, 2006
- High-resolution image reconstruction method for time-of-flight positron emission tomographyPhysics in Medicine & Biology, 2000