DNA degradation in liquid‐based cytology and its comparison with conventional smear
Authors:
- 23 January 2016
- journal article
- research article
- Published by Wiley in Diagnostic Cytopathology
- Vol. 44 (5) , 450-458
Abstract
Background In fine needle aspiration biopsy (FNAB) of thyroid nodules, LBC is adopted in most of the hospitals and clinics in Korea for its convenience. BRAF mutation test has been introduced as an important ancillary test, but its applicability has not been completely proven with LBC samples. Methods Five aspirates from thyroidectomy specimens were simultaneously processed into LBC and CS slides, in which BRAF mutation tests were performed using three primer sets with PCR products of 72, 164, and 226 base pairs (bp) at 6, 9, and 12 months after processing. In addition, BRAF mutation tests were performed in nine clinical samples that had been prepared by LBC or CS and stored for 3–5 years after processing. Results At 9 months after processing, LBC failed to provide DNA of sufficient quality for PCR, whereas CS succeeded with primers for amplifying a 226 bp fragment. Furthermore, CS had successful amplification of DNA despite a delay of more than 1 year. The failure of DNA amplification in LBC was overcome by using primers to amplify shorter PCR products, suggesting that DNA degradation occurred in LBC. However, false positive or negative results were observed in primers for amplifying shorter size. The kind of preservative solutions used in LBC did not affect test results. Conclusion LBC may have disadvantages in long-term DNA preservation because of its accelerated DNA degradation compared with alcohol-fixed CS. Using primers to amplify shorter size fragments might be helpful in mitigating loss of signal due to DNA degradation in LBC. Diagn. Cytopathol. 2016.Keywords
This publication has 19 references indexed in Scilit:
- Development of an Ammonium Sulfate DNA Extraction Method for Obtaining Amplifiable DNA in a Small Number of Cells and Its Application to Clinical SpecimensBioMed Research International, 2013
- Clinical Usefulness of SurePath™ Liquid-based Cytology in Thyroid Fine Needle Aspiration: Comparison with the Conventional Smear in Diagnostic Efficacy and Applicability ofBRAFMutation TestThe Korean Journal of Pathology, 2011
- Detection ofBRAFMutations in Thyroid Nodules by Allele-Specific PCR Using a Dual Priming Oligonucleotide SystemAmerican Journal of Clinical Pathology, 2010
- Diagnostic Efficacy of Conventional as Compared to Liquid-Based Cytology in Thyroid LesionsActa Cytologica, 2009
- Pyrosequencing Analysis for Detection of a BRAFV600E Mutation in an FNAB Specimen of Thyroid NodulesDiagnostic Molecular Pathology, 2008
- The role of liquid‐based cytology in the investigation of thyroid lesionsCytopathology, 2007
- p63 Immunocytochemistry Improves Accuracy of Diagnosis With Fine-Needle Aspiration of the BreastAmerican Journal of Clinical Pathology, 2007
- Detection of BRAFV600E mutation on fine needle aspiration specimens of thyroid nodule refines cyto‐pathology diagnosis, especially in BRAFV600E mutation‐prevalent areaClinical Endocrinology, 2006
- Thyroid fine needle aspiration: the morphological features on ThinPrep® slide preparations. Eighty cases with histological controlCytopathology, 2003
- Fundamental study on the mechanism of DNA degradation in tissues fixed in formaldehyde.Journal of Clinical Pathology, 1990