Improved electronic measurement of the Boltzmann constant by Johnson noise thermometry

Authors:

Abstract
The unit of thermodynamic temperature, the kelvin, will be redefined in 2018 by fixing the value of the Boltzmann constant, k . The present CODATA recommended value of k is determined predominantly by acoustic gas-thermometry results. To provide a value of k based on different physical principles, purely electronic measurements of k were performed by using a Johnson noise thermometer to compare the thermal noise power of a 200 Ω sensing resistor immersed in a triple-point-of-water cell to the noise power of a quantum-accurate pseudo-random noise waveform of nominally equal noise power. Measurements integrated over a bandwidth of 575 kHz and a total integration time of about 33 d gave a measured value of k = 1.3806513(53) × 10 −23 J K −1 , for which the relative standard uncertainty is 3.9 × 10 −6 and the relative offset from the CODATA 2010 value is +1.8 × 10 −6 .
All Related Versions
Funding Information
  • National Natural Science Foundation of China (61001034, 61372041)

This publication has 45 references indexed in Scilit: