Diagnostic accuracy of serum matrix metalloproteinase-7 as a biomarker of biliary atresia in a large North American cohort
Author:
Open Access
- 6 March 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Hepatology
- Vol. 80 (1) , 152-162
Abstract
Background and Aims: High levels of serum matrix metalloproteinase-7 (MMP-7) have been linked to biliary atresia (BA), with wide variation in concentration cutoffs. We investigated the accuracy of serum MMP-7 as a diagnostic biomarker in a large North American cohort. Approach and Results: MMP-7 was measured in serum samples of 399 infants with cholestasis in the Prospective Database of Infants with Cholestasis study of the Childhood Liver Disease Research Network, 201 infants with BA and 198 with non-BA cholestasis (age median: 64 and 59 days, p = 0.94). MMP-7 was assayed on antibody-bead fluorescence (single-plex) and time resolved fluorescence energy transfer assays. The discriminative performance of MMP-7 was compared with other clinical markers. On the single-plex assay, MMP-7 generated an AUROC of 0.90 (CI: 0.87–0.94). At cutoff 52.8 ng/mL, it produced sensitivity = 94.03%, specificity = 77.78%, positive predictive value = 64.46%, and negative predictive value = 96.82% for BA. AUROC for gamma-glutamyl transferase = 0.81 (CI: 0.77–0.86), stool color = 0.68 (CI: 0.63–0.73), and pathology = 0.84 (CI: 0.76–0.91). Logistic regression models of MMP-7 with other clinical variables individually or combined showed an increase for MMP-7+gamma-glutamyl transferase AUROC to 0.91 (CI: 0.88–0.95). Serum concentrations produced by time resolved fluorescence energy transfer differed from single-plex, with an optimal cutoff of 18.2 ng/mL. Results were consistent within each assay technology and generated similar AUROCs. Conclusions: Serum MMP-7 has high discriminative properties to differentiate BA from other forms of neonatal cholestasis. MMP-7 cutoff values vary according to assay technology. Using MMP-7 in the evaluation of infants with cholestasis may simplify diagnostic algorithms and shorten the time to hepatoportoenterostomy.Keywords
This publication has 26 references indexed in Scilit:
- Fractionated Bilirubin Among 252 892 Utah Newborns with and Without Biliary Atresia: A 15-year Historical Birth Cohort StudyThe Journal of Pediatrics, 2023
- Comparing Serum Matrix Metalloproteinase-7 in Parenteral Nutrition-Associated Liver Disease and Biliary AtresiaThe Journal of Pediatrics, 2022
- Newborn Screening for Biliary Atresia: a Review of Current MethodsCurrent Gastroenterology Reports, 2021
- Diagnostic Yield of Newborn Screening for Biliary Atresia Using Direct or Conjugated Bilirubin MeasurementsJAMA, 2020
- RNA-seq reveals outcome-specific gene expression of MMP7 and PCK1 in biliary atresiaMolecular Biology Reports, 2019
- Quantification of Serum Matrix Metallopeptide 7 Levels May Assist in the Diagnosis and Predict the Outcome for Patients with Biliary AtresiaThe Journal of Pediatrics, 2019
- Diagnostic Accuracy of Serum Matrix Metalloproteinase‐7 for Biliary AtresiaHepatology, 2018
- Biliary Atresia: Clinical and Research Challenges for the Twenty‐First CenturyHepatology, 2018
- Biliary atresia: A comprehensive reviewJournal of Autoimmunity, 2016
- Increased MMP‐7 expression in biliary epithelium and serum underpins native liver fibrosis after successful portoenterostomy in biliary atresiaThe Journal of Pathology: Clinical Research, 2016