Evaluation of optic nerve head changes with optic coherence tomography in patients with idiopathic intracranial hypertension
Authors:
- 17 August 2018
- journal article
- research article
- Published by Springer Nature in Acta Neurologica Belgica
- Vol. 119 (3) , 351-357
Abstract
In the case of mild papilledema, fundoscopy findings may sometimes be insufficient, leading to false and misleading indices in the diagnosis of early-stage idiopathic intracranial hypertension (IIH). This study aims to evaluate these patients through optic coherence tomography (OCT). The study included 54 individuals diagnosed with IIH and 48 healthy individuals in the control group. All patients underwent neurological and ophthalmologic examinations. Opening pressure values of patients’ cerebrospinal fluid (CSF) were recorded. We measured the thickness of the retinal nerve fiber layer (RNFL) and the ganglion cell complex, cup volume, and the optical disc area, as well as the neuroretinal rim in both groups. A total of 108 eyes from the patient group and 96 eyes from the control group were evaluated. It was found that the mean value of the RNFL thickness of the IIH patients was greater than the control group in the following eight segments: superior nasal, superior temporal, inferior nasal, inferior temporal, nasal superior, nasal inferior, temporal superior, and temporal inferior (p < 0.01 for all). In contrast to the control group, the disc and rim area values of the patient group were higher (p < 0.01), while the cup volume was smaller (p < 0.01) than in the control group. In the patient group, a positive correlation was observed between the papilledema grade and the RNFL thickness (r = 0.64, p < 0.01), CSF opening pressure (r = 0.59, p < 0.01), disc area (r = 0.68, p < 0.01), and rim area (r = 0.70, p < 0.01). Furthermore, RNFL thickness, CSF opening pressure (r = 0.61, p < 0.01), disc area (r = 0.71, p < 0.01), and rim area (r = 0.71, p < 0.01) values were determined to be positively correlated to each other. OCT is believed to contribute to the diagnosis of IIH, by providing reliable data on optical cup volume, optical disc and rim area, and a greater RNFL thickness.Keywords
This publication has 26 references indexed in Scilit:
- The International Classification of Headache Disorders, 3rd edition (beta version)Cephalalgia, 2013
- Quantitative analysis of optic nerve damage in idiopathic intracranial hypertension (IIH) at diagnosisNeurological Sciences, 2013
- Diagnostic value of optical coherence tomography for intracranial pressure in idiopathic intracranial hypertensionGraefe's Archive for Clinical and Experimental Ophthalmology, 2012
- Optic Nerve Head Quantification in Idiopathic Intracranial Hypertension by Spectral Domain OCTPLOS ONE, 2012
- Accuracy of Funduscopy to Identify True Edema versus Pseudoedema of the Optic DiscInvestigative Ophthalmology & Visual Science, 2012
- OCT assessment of morphological changes of the optic nerve head and macula in idiopathic intracranial hypertensionClinical Neurology and Neurosurgery, 2011
- The syndrome of pseudotumour cerebri and idiopathic intracranial hypertensionCurrent Opinion in Neurology, 2011
- Use of Optical Coherence Tomography to Evaluate Papilledema and PseudopapilledemaSeminars in Ophthalmology, 2010
- Follow-up of Mild Papilledema in Idiopathic Intracranial Hypertension with Optical Coherence TomographyInvestigative Ophthalmology & Visual Science, 2009
- Optical coherence tomography as a tool for monitoring pediatric pseudotumor cerebriJournal of American Association for Pediatric Ophthalmology and Strabismus, 2007