We investigate the influence of mechanical strain on the critical current (Ic) for magnesium diboride/stainless steel (SUS316) superconducting tapes. The tensile axial strain along the tape length is successfully induced in the sample by using a U-shaped holder made of stainless steel (SUS304). Two samples are examined at 4.2 K and 5 T (B is applied perpendicular to the tape surface). The Ic–strain relation can be divided into two regions. Rapid and large degradation occurs at a strain exceeding ~0.5%. On the other hand, Ic change is reversible against strain change between −0.4% (compressive strain) and 0.4%. Ic increases and decreases with increasing and decreasing external strain in this region, respectively. The critical temperature (Tc) also changes with the change in the external strain; Tc increases with increasing external strain. The reversible change in Ic originates in the change of Tc.