Automatic Segmentation of Intracochlear Anatomy in Conventional CT
- 23 June 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (9) , 2625-2632
Abstract
Cochlear implant surgery is a procedure performed to treat profound hearing loss. Clinical results suggest that implanting the electrode in the scala tympani, one of the two principal cavities inside the cochlea, may result in better hearing restoration. Segmentation of intracochlear cavities could thus aid the surgeon to choose the point of entry and angle of approach that maximize the likelihood of successful implant insertion, which may lead to more substantial hearing restoration. However, because the membrane that separates the intracochlear cavities is too thin to be seen in conventional in vivo imaging, traditional segmentation techniques are inadequate. In this paper, we circumvent this problem by creating an active shape model with micro CT (μCT) scans of the cochlea acquired ex vivo. We then use this model to segment conventional CT scans. The model is fitted to the partial information available in the conventional scans and used to estimate the position of structures not visible in these images. Quantitative evaluation of our method, made possible by the set of μCTs, results in Dice similarity coefficients averaging 0.75. Mean and maximum surface errors average 0.21 and 0.80 mm.Keywords
This publication has 25 references indexed in Scilit:
- Anatomic verification of a novel method for precise intrascalar localization of cochlear implant electrodes in adult temporal bones using clinically available computed tomographyThe Laryngoscope, 2010
- Clinical Validation Study of Percutaneous Cochlear Access Using Patient-Customized Microstereotactic FramesOtology & Neurotology, 2010
- Variational Anatomy of the Human CochleaOtology & Neurotology, 2009
- Role of Electrode Placement as a Contributor to Variability in Cochlear Implant OutcomesOtology & Neurotology, 2008
- Quality Control After Insertion of the Nucleus Contour and Contour Advance Electrode in AdultsEar & Hearing, 2007
- An overlap invariant entropy measure of 3D medical image alignmentPattern Recognition, 1999
- Compactly supported positive definite radial functionsAdvances in Computational Mathematics, 1995
- Active Shape Models-Their Training and ApplicationComputer Vision and Image Understanding, 1995
- Morphometric analysis of white matter lesions in MR images: method and validationIEEE Transactions on Medical Imaging, 1994
- Measures of the Amount of Ecologic Association Between SpeciesEcology, 1945