The Use of Adaptive Statistical Iterative Reconstruction in Pediatric Head CT: A Feasibility Study
Authors:
Open Access
- 24 May 2012
- journal article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 34 (1) , 205-211
Abstract
BACKGROUND AND PURPOSE: Iterative reconstruction techniques facilitate CT dose reduction; though to our knowledge, no group has explored using iterative reconstruction with pediatric head CT. Our purpose was to perform a feasibility study to assess the use of ASIR in a small group of pediatric patients undergoing head CT. MATERIALS AND METHODS: An Alderson-Rando head phantom was scanned at decreasing 10% mA intervals relative to our standard protocol, and each study was then reconstructed at 10% ASIR intervals. An intracranial region of interest was consistently placed to estimate noise. Our ventriculoperitoneal shunt CT protocol was subsequently modified, and patients were scanned at 20% ASIR with approximately 20% mA reductions. ASIR studies were anonymously compared with older non-ASIR studies from the same patients by 2 attending pediatric neuroradiologists for diagnostic utility, sharpness, noise, and artifacts. RESULTS: The phantom study demonstrated similar noise at 100% mA/0% ASIR (3.9) and 80% mA/20% ASIR (3.7). Twelve pediatric patients were scanned at reduced dose at 20% ASIR. The average CTDIvol and DLP values of the 20% ASIR studies were 22.4 mGy and 338.4 mGy-cm, and for the non-ASIR studies, they were 28.8 mGy and 444.5 mGy-cm, representing statistically significant decreases in the CTDIvol (22.1%, P = .00007) and DLP (23.9%, P = .0005) values. There were no significant differences between the ASIR studies and non-ASIR studies with respect to diagnostic acceptability, sharpness, noise, or artifacts. CONCLUSIONS: Our findings suggest that 20% ASIR can provide approximately 22% dose reduction in pediatric head CT without affecting image quality.Keywords
This publication has 29 references indexed in Scilit:
- Lowering the Dose in Head CT Using Adaptive Statistical Iterative ReconstructionAmerican Journal of Neuroradiology, 2011
- Low-Dose MDCT and CT Enterography of Patients With Crohn Disease: Feasibility of Adaptive Statistical Iterative ReconstructionAmerican Journal of Roentgenology, 2011
- Abdominal CT: Comparison of Low-Dose CT With Adaptive Statistical Iterative Reconstruction and Routine-Dose CT With Filtered Back Projection in 53 PatientsAmerican Journal of Roentgenology, 2010
- Diffuse Lung Disease: CT of the Chest with Adaptive Statistical Iterative Reconstruction TechniqueRadiology, 2010
- A comparison of radiation doses between state-of-the-art multislice CT coronary angiography with iterative reconstruction, multislice CT coronary angiography with standard filtered back-projection and invasive diagnostic coronary angiographyHeart, 2010
- Reducing Abdominal CT Radiation Dose With Adaptive Statistical Iterative Reconstruction TechniqueInvestigative Radiology, 2010
- Low-Tube-Voltage, High-Tube-Current Multidetector Abdominal CT: Improved Image Quality and Decreased Radiation Dose with Adaptive Statistical Iterative Reconstruction Algorithm—Initial Clinical ExperienceRadiology, 2010
- MEDICAL RADIATION EXPOSURE IN THE U.S. IN 2006: PRELIMINARY RESULTSHealth Physics, 2008
- Low-Dose Nonenhanced Head CT Protocol for Follow-Up Evaluation of Children with Ventriculoperitoneal Shunt: Reduction of Radiation and Effect on Image QualityAmerican Journal of Neuroradiology, 2008
- Radiation Dose-Reduction Strategies for Neuroradiology CT ProtocolsAmerican Journal of Neuroradiology, 2007