Energy and ventilation performance analysis for CO 2 -based demand-controlled ventilation in multiple-zone VAV systems with fan-powered terminal units (ASHRAE RP-1819)
Authors:
- 18 October 2020
- journal article
- research article
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 27 (2) , 139-157
Abstract
CO2-based demand-controlled ventilation (DCV) has been proved to be energy-efficient by altering ventilation rates according to surrogated indications of CO2 levels in single- and multiple-zone single-path variable air volume (VAV) systems. However, DCV for multiple-zone VAV systems with multiple recirculation paths is still untapped. Multiple-zone VAV systems with series and parallel fan-powered terminal units (FPTUs) are studied in this study. Energy and ventilation performance of the DCV strategies with dynamic resets are evaluated. The DCV control sequences for FPTUs are first summarized. A co-simulation approach combining EnergyPlus with CONTAM is adopted. The DCV controls are implemented in the EnergyPlus energy management system (EMS) module. New EnergyPlus EMS actuators are added and a customized EnergyPlus module is built to achieve the DCV control for each system. An office building is used to demonstrate the benefits from the proposed DCV strategies in four different U.S. climates zones. Two baselines for ventilation requirements (ASHRAE 62.1, California Title 24) are considered. The proposed DCV strategies resulted in 7–14% and 7–21% HVAC energy savings for each system, on a source energy basis, compared with the baseline of a simplified ASHRAE 62.1 approach. Both systems could achieve good compliance with the ventilation requirements in ASHRAE Standard 62.1.Keywords
Funding Information
- American Society of Heating, Refrigerating and Air-Conditioning Engineers (RP-1819)
This publication has 15 references indexed in Scilit:
- A model-based control of CO2 concentration in multi-zone ACB air-conditioning systems2016
- Coupling the multizone airflow and contaminant transport software CONTAM with EnergyPlus using co-simulationBuilding Simulation, 2016
- A state-feedback approach for controlling ventilation systems in energy efficient buildings2015
- Demand-controlled ventilation for multiple-zone HVAC systems—Part 2: CO 2 -based dynamic reset with zone primary airflow minimum set-point reset (RP-1547)Science and Technology for the Built Environment, 2015
- CO 2 sensors for occupancy estimations: Potential in building automation applicationsEnergy and Buildings, 2014
- Demand controlled ventilation for multiple zone HVAC systems: CO 2 -based dynamic reset (RP 1547)HVAC&R Research, 2014
- Control of indoor CO2 concentration based on a process modelAutomation in Construction, 2014
- A new method for controlling CO2 in buildings with unscheduled opening hoursEnergy and Buildings, 2013
- A robust CO2-based demand-controlled ventilation control strategy for multi-zone HVAC systemsEnergy and Buildings, 2012
- A novel and dynamic demand-controlled ventilation strategy for CO2 control and energy saving in buildingsEnergy and Buildings, 2011