Effect of repetitive pecking at working length for glide path preparation using G-file
Open Access
- 1 January 2015
- journal article
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 40 (2) , 123-7
Abstract
Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi) rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. The G-file system (Micro-Mega) composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10). Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0) and 1 mm level (D1) under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05). The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05). Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO) size 20, without apical transportation at D0 level.Keywords
This publication has 20 references indexed in Scilit:
- Incidence of Dentinal Defects after Root Canal Preparation: Reciprocating versus Rotary InstrumentationJournal of Endodontics, 2013
- Mechanical Behavior of Pathfinding Endodontic InstrumentsJournal of Endodontics, 2012
- Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canalsRestorative Dentistry & Endodontics, 2012
- The endodontic Glidepath: "Secret to rotary safety".2010
- Use of Nickel-Titanium Rotary PathFile to Create the Glide Path: Comparison With Manual Preflaring in Simulated Root CanalsJournal of Endodontics, 2009
- Instrument fracture: mechanisms, removal of fragments, and clinical outcomesEndodontic Topics, 2007
- Endodontic Update 2006Journal of Esthetic and Restorative Dentistry, 2006
- The ProTaper techniqueEndodontic Topics, 2005
- A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canalsOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2003
- A comparison of Greater Taper files, ProFiles, and stainless steel files to shape curved root canalsOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2001