Human amniotic membrane plug to promote failed macular hole closure
Open Access
- 26 October 2020
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-8
Abstract
The failed macular hole is a full-thickness defect involving the fovea that fails to close despite 1 or more surgeries. While many surgical options have been proposed to manage it, none of these guarantee complete anatomical success and satisfactory visual recovery. We report postoperative outcomes on 36 patients affected by failed macular hole, treated with a human amniotic membrane plug transplant. Follow-ups were performed with a standard ophthalmological examination and with advanced multimodal diagnostic imaging. Anatomical closure was achieved at 3 months in all patients. Mean best-corrected visual acuity improved statistically significantly at 6 months (p < 0.05). Through microperimetric tests, we assessed a partial recovery of the macular sensitivity on the edges of the plug. Analyzing SD-OCT images, we reported a tissutal ingrowth above the plug, and its segmentation into layers, mimicking normal retinal architecture. OCT-Angiography images non invasively analysed the retinal parafoveal capillary microvasculature; the elaboration of Adaptive Optics images showed the presence of photoreceptors at the edges of the plug. This work demonstrates not only the complete anatomical success of our technique, but also remarkable functional results, and opens the door to a greater understanding of modifications induced by the presence of a human amniotic membrane plug.Keywords
This publication has 31 references indexed in Scilit:
- ASSESSING PHOTORECEPTOR STRUCTURE AFTER MACULAR HOLE CLOSURERETINAL Cases & Brief Reports, 2015
- Autologous Transplantation of the Internal Limiting Membrane for Refractory Macular HolesAmerican Journal of Ophthalmology, 2014
- Objective Assessment of Foveal Cone Loss Ratio in Surgically Closed Macular Holes Using Adaptive Optics Scanning Laser OphthalmoscopyPLOS ONE, 2013
- Photoreceptor Damage and Foveal Sensitivity in Surgically Closed Macular Holes: An Adaptive Optics Scanning Laser Ophthalmoscopy StudyAmerican Journal of Ophthalmology, 2012
- Inverted Internal Limiting Membrane Flap Technique for Large Macular HolesOphthalmology, 2010
- Incidence and Factors Related to Macular Hole ReopeningAmerican Journal of Ophthalmology, 2010
- Reopening of Previously Closed Macular Holes After Cataract ExtractionAmerican Journal of Ophthalmology, 2007
- Surgical management of macular holesOphthalmology, 2001
- Long-term incidence of reopening of macular holes11The authors have no proprietary interest in any product used in this study.Ophthalmology, 2000
- Treatment of reopened macular hole after vitrectomy by laser and outpatient fluid-gas exchangeOphthalmology, 1998