Reconstruction of conductivity changes and electrode movements based on EIT temporal sequences
Authors:
- Camille Gómez-LabergeCGCamille Gómez-Laberge
- Andy AdlerAAAndy Adler
- 1 June 2008
- journal article
- clinical trial
- Published by IOP Publishing in Physiological Measurement
- Vol. 29 (6) , S77-S88
Abstract
Electrical impedance tomography (EIT) reconstructs a conductivity change image within a body from electrical measurements on the body surface; while it has relatively low spatial resolution, it has a high temporal resolution. One key difficulty with EIT measurements is due to the movement and position uncertainty of the electrodes, especially due to breathing and posture change. In this paper, we develop an approach to reconstruct both the conductivity change image and the electrode movements from the temporal sequence of EIT measurements. Since both the conductivity change and electrode movement are slow with respect to the data frame rate, there are significant temporal correlations which we formulate as priors for the regularized image reconstruction model. Image reconstruction is posed in terms of a regularization matrix and a Jacobian matrix which are augmented for the conductivity change and electrode movement, and then further augmented to concatenate the d previous and future frames. Results are shown for simulation, phantom and human data, and show that the proposed algorithm yields improved resolution and noise performance in comparison to a conventional one-step reconstruction method.Keywords
This publication has 26 references indexed in Scilit:
- Electrode placement configurations for 3D EITPhysiological Measurement, 2007
- Temporal image reconstruction in electrical impedance tomographyPhysiological Measurement, 2007
- EIT images of ventilation: what contributes to the resistivity changes?Physiological Measurement, 2005
- Modeling Inverse Covariance Matricesby Basis ExpansionIEEE Transactions on Speech and Audio Processing, 2004
- A Matlab toolkit for three-dimensional electrical impedance tomography: a contribution to the Electrical Impedance and Diffuse Optical Reconstruction Software projectMeasurement Science and Technology, 2002
- Determination of stroke volume by means of electrical impedance tomographyPhysiological Measurement, 2000
- Clinical applications of electrical impedance tomography in the monitoring of changes in intrathoracic fluid volumesPhysiological Measurement, 1994
- Review Clinical applications of electrical impedance tomographyJournal of Medical Engineering & Technology, 1993
- NOSER: An algorithm for solving the inverse conductivity problemInternational Journal of Imaging Systems and Technology, 1990
- An assessment of dynamic images by applied potential tomography for monitoring pulmonary perfusionClinical Physics and Physiological Measurement, 1988