Performance of a fully automated quantitative neopterin measurement assay in a routine voluntary blood donation setting
- 18 December 2009
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 48 (3) , 373-377
Abstract
Background:Acute virus infections are indicated by increased serum neopterin concentrations. Testing of blood donations for increased neopterin was introduced in the Austrian Tyrol in 1986 and throughout Austria in 1994 to improve the safety of blood transfusions. Radioimmunoassay (RIA) was the first available test, and the 98th percentile for neopterin concentrations from 76,500 donations was defined as the cut-off threshold, excluding donations with neopterin ≥10 nmol/L. When ELISAs were introduced on fully automated test systems to measure neopterin concentrations, results were generally higher and the cut-off was adjusted up to 12 nmol/L.Methods:In early 2006, new equipment (Hamilton Microlab Star®pipettor+Dade Behring ELISA Processor III, BEP III®) became available which monitors sample and reagent volumes for each uptake and dispense, and takes the viscosity of the fluids into account. Using this system, the performance of neopterin determinations was evaluated over 21 months and compared to earlier data.Results:When the new apparatuses were introduced, an immediate decrease in mean neopterin concentrations and the percentage of samples with neopterin concentrations ≥10 nmol/L was observed. The 55,516 measurements performed in 2007 showed a mean value of 5.5 nmol/L. Neopterin in 680 donations (1.23%) were ≥10 nmol/L.Conclusions:The new Hamilton diluter increased the accuracy of the neopterin test procedure. Results are now identical with those of RIA and ELISA when run in a semi-automated manner. Differences in pipetting performance of standards and samples are considered as one possible explanation for the earlier discrepancies seen with the automated apparatus.Clin Chem Lab Med 2010;48:373–7.Keywords
This publication has 14 references indexed in Scilit:
- Neopterin as a Predictor of Total and Cardiovascular Mortality in Individuals Undergoing Angiography in the Ludwigshafen Risk and Cardiovascular Health StudyClinical Chemistry, 2009
- Pathogen Reduction: A Precautionary Principle ParadigmTransfusion Medicine Reviews, 2008
- High prevalence of cytomegalovirus DNA in plasma samples of blood donors in connection with seroconversionTransfusion, 2007
- Elevated serum neopterin predicts future adverse cardiac events in patients with chronic stable angina pectorisEuropean Heart Journal, 2005
- The value of increased neopterin levels in reducing transfusion-transmitted virus infections: detection of a donation from a HBsAg positive chronic carrier by screening of neopterin in Turkish blood donorsScandinavian Journal of Infectious Diseases, 2005
- Reducing HIV transmission by seronegative bloodThe Lancet, 1992
- Immunological changes in primary HIV-1 infectionAIDS, 1990
- Serum-Neopterinbestimmung zur zusätzlichen Sicherung der Bluttransfusion: Erfahrungen an 76 587 BlutspendernDMW - Deutsche Medizinische Wochenschrift, 1989
- Neopterin as a marker for activated cell-mediated immunity: Application in HIV infectionImmunology Today, 1988
- Immune response-associated production of neopterin. Release from macrophages primarily under control of interferon-gamma.Journal of Experimental Medicine, 1984