Detection of residual brain arteriovenous malformations after radiosurgery: diagnostic accuracy of contrast-enhanced four-dimensional MR angiography at 3.0 T
Authors:
- C G ChoiCCC G Choi
- S M KimSKS M Kim
- J L KimJKJ L Kim
- D H LeeDLD H Lee
- S J KimSKS J Kim
- D C SuhDSD C Suh
- 1 August 2012
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 85 (1016) , 1064-1069
Abstract
Objective: To evaluate the diagnostic accuracy of four-dimensional MR angiography (4D-MRA) at 3.0 T for detecting residual arteriovenous malformations (AVMs) after Gamma Knife® (Elekta Instrument AB, Stockholm, Sweden) radiosurgery (GKRS). Methods: We assessed 36 angiographically confirmed AVMs in 36 patients who had been treated with GKRS. 4D-MRA was performed after GKRS and the time intervals were 39.4±26.0 months [mean±standard deviation (SD)]. 4D-MRA was obtained at 3.0 T after contrast injection, with a measured voxel size of 1×1×1 mm and a temporal resolution of 1.1 s (13 patients) or a voxel size of 1×1×2 mm and a temporal resolution of 0.98 s (23 patients). X-ray angiography was performed as the standard reference within 53±47 days (mean±SD) after MRA. To determine a residual AVM, the 4D-MRA results were independently reviewed by two readers blinded to the X-ray angiography results. We evaluated diagnostic sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 4D-MRA for detection of a residual AVM. Results: A residual AVM was identified in 13 patients (13/36, 36%) on X-ray angiography. According to Readers 1 and 2, 4D-MRA had a sensitivity of 79.6% and 64.3%, a specificity of 90.9% and 100%, a PPV of 84.6% and 100% and an NPV of 90% and 81.5%, respectively, and a diagnostic accuracy of 86.1% for Readers 1 and 2, for detecting residual AVMs after GKRS. Conclusion: The diagnostic accuracy of 4D-MRA at 3.0 T seems high, but there is still the possibility of further improving the spatiotemporal resolution of this technique.Keywords
This publication has 21 references indexed in Scilit:
- The role of time-resolved 3D contrast-enhanced MR angiography in the assessment and grading of cerebral arteriovenous malformationsEuropean Journal of Radiology, 2010
- On Improving Temporal and Spatial Resolution of 3D Contrast-enhanced Body MR Angiography with Parallel ImagingRadiology, 2004
- Three-dimensional MR digital subtraction angiography using parallel imaging and keyhole data sampling in cerebrovascular diseases: initial experienceEuropean Radiology, 2004
- Patient Outcomes after Arteriovenous Malformation Radiosurgical Management: Results Based on a 5- to 14-year Follow-up StudyNeurosurgery, 2003
- Neurologic Complications of Cerebral Angiography: Prospective Analysis of 2,899 Procedures and Review of the LiteratureRadiology, 2003
- An analysis of the dose–response for arteriovenous malformation radiosurgery and other factors affecting obliterationRadiotherapy and Oncology, 2002
- Contrast-enhanced 3D MRA using SENSEJournal of Magnetic Resonance Imaging, 2000
- Histopathology of arteriovenous malformations after gamma knife radiosurgeryJournal of Neurosurgery, 1997
- Linear accelerator radiosurgery for arteriovenous malformations: the relationship of size to outcomeJournal of Neurosurgery, 1995
- The natural history of symptomatic arteriovenous malformations of the brain: a 24-year follow-up assessmentJournal of Neurosurgery, 1990