Response of Fiber Reinforced Polymer Confined Concrete Exposed to Freeze and Freeze-Thaw Regimes
- 1 February 2002
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 6 (1) , 35-40
Abstract
Unidirectional carbon/vinylester composites and concrete cylinders wrapped with three layers of the same composite were exposed to −18°C (0°F) conditions both with and without prior saturation by moisture and to freeze-thaw cycling after saturation. All specimens show degradation in strength, with the maximum degradation being due to the saturated freeze-thaw condition caused by cyclic effects of absorption, subsequent crack-opening and fiber-matrix debonding. Analytical predictions, based on approximation of hygrothermomechanical response models for composites combined with a simple confinement model, are shown to correlate well with experimental data for most of the exposure conditions.Keywords
This publication has 7 references indexed in Scilit:
- Effect of Short-Term Freeze-Thaw Cyclingon Composite Confined ConcreteJournal of Composites for Construction, 2000
- Composite Jacketed Concrete under Uniaxial Compression—Verification of Simple Design EquationsJournal of Materials in Civil Engineering, 1997
- Low-Temperature Compressive Strength of Glass-Fiber-Reinforced Polymer CompositesJournal of Offshore Mechanics and Arctic Engineering, 1994
- Structural Fiber Composite Materials for Cold RegionsJournal of Cold Regions Engineering, 1988
- Durability/Life of Fiber Composites in Hygrothermomechanical Environments1982
- Mechanical and Electrical Low Temperature Properties of High Polymers1979
- Polymers in Low Temperature Technology1979