Coronary Artery Motion and Cardiac Phases: Dependency on Heart Rate—Implications for CT Image Reconstruction
Authors:
- Sebastian LeschkaSLSebastian Leschka
- Lotus DesbiollesLDLotus Desbiolles
- Tiziano SchepisTSTiziano Schepis
- Oliver GaemperliOGOliver Gaemperli
- Burkhardt SeifertBSBurkhardt Seifert
- Philippe CattinPCPhilippe Cattin
- Thomas FrauenfelderThomas Frauenfelder
- Thomas G. FlohrTFThomas G. Flohr
- Borut MarincekBMBorut Marincek
- Philipp A. KaufmannPKPhilipp A. Kaufmann
- Hatem AlkadhiHatem Alkadhi
- 1 November 2007
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 245 (2) , 567-576
Abstract
This study had institutional review board approval; written informed consent was obtained. The purpose was to prospectively determine the heart rate (HR) dependency of three-dimensional (3D) coronary artery motion by incorporating into analysis the durations of systole and diastole. Thirty patients (seven women, 23 men; mean age, 56.6 years ± 12.7 [standard deviation]; HR: 45–100 beats per minute) underwent electrocardiographically gated 64-section computed tomographic (CT) coronary angiography to determine coronary motion velocities at bifurcation points. Significance of velocity differences (P < .05) was determined by using analysis of variance for repeated measures and Bonferroni post hoc tests. HR dependency was determined by using linear regression analysis. HR significantly affected 3D coronary motion (r = 0.47, P < .009) through nonproportional shortening of systole and diastole (r = −0.82, P < .001), leading to percentage reconstruction interval shifts of coronary velocity troughs and peaks (P < ....Keywords
This publication has 35 references indexed in Scilit:
- Image Quality, Motion Artifacts, and Reconstruction Timing of 64-Slice Coronary Computed Tomography Angiography With 0.33-Second Rotation SpeedInvestigative Radiology, 2006
- Dynamic Cine Mode Imaging of the Normal Aortic Valve Using 16-Channel Multidetector Row Computed TomographyInvestigative Radiology, 2005
- Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed TomographyJACC, 2005
- Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed TomographyJACC, 2005
- Accuracy of MSCT coronary angiography with 64-slice technology: first experienceEuropean Heart Journal, 2005
- On the potential of measurement error to induce differential bias on odds ratio estimates: an example from radon epidemiologyStatistics in Medicine, 2002
- A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart AssociationCirculation, 1975
- The phases of the cardiac cycleAmerican Heart Journal, 1972
- Assessment of regional myocardial performance from biplane coronary cineangiogramsThe American Journal of Cardiology, 1971
- A Coefficient of Agreement for Nominal ScalesEducational and Psychological Measurement, 1960