Reduction of cement leakage by sequential PMMA application in a vertebroplasty model
- 5 April 2015
- journal article
- Published by Springer Nature in European Spine Journal
- Vol. 25 (11) , 3450-3455
Abstract
Leakage is the most common complication of percutaneous cement augmentation of the spine. The viscosity of the polymethylmethacrylate (PMMA) cement is strongly correlated with the likelihood of cement leakage. We hypothesized that cement leakage can be reduced by sequential cement injection in a vertebroplasty model. A standardized vertebral body substitute model, consisting of aluminum oxide foams coated by acrylic cement with a preformed leakage path, simulating a ventral vein, was developed. Three injection techniques of 6 ml PMMA were assessed: injection in one single step (all-in-one), injection of 1 ml at the first and 5 ml at the second step with 1 min latency in-between (two-step), and sequential injection of 0.5 ml with 1-min latency between the sequences (sequential). Standard PMMA vertebroplasty cement was used; each injection type was tested on ten vertebral body substitute models with two possible leakage paths per model. Leakage was assessed by radiographs using a zonal graduation: intraspongious = no leakage and extracortical = leakage. The leakage rate was significantly lower in the “sequential” technique (2/20 leakages) followed by “two-step” (15/20) and “all-in-one” (20/20) techniques (p < 0.001). The RR for a cement leakage was 10.0 times higher in the “all-in-one” compared to the “sequential” group (95 % confidence intervals 2.7–37.2; p < 0.001). The sequential cement injection is a simple approach to minimize the risk for leakage. Taking advantage of the temperature gradient between body and room temperature, it is possible to increase the cement viscosity inside the vertebra while keeping it low in the syringe. Using sequential injection of small cement volumes, further leakage paths are blocked before further injection of the low-viscosity cement.Keywords
This publication has 19 references indexed in Scilit:
- Cement volume is the most important modifiable predictor for pain relief in BKP: results from SWISSspine, a nationwide registryEuropean Spine Journal, 2013
- Comparing effects of kyphoplasty, vertebroplasty, and non-surgical management in a systematic review of randomized and non-randomized controlled studiesEuropean Spine Journal, 2012
- Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factorsThe Spine Journal, 2011
- Cardiovascular changes after PMMA vertebroplasty in sheep: the effect of bone marrow removal using pulsed jet-lavageEuropean Spine Journal, 2010
- Clinical Experience with High-Viscosity Cements for Percutaneous Vertebral Body Augmentation: Occurrence, Degree, and Location of Cement Leakage Compared with KyphoplastyAmerican Journal of Neuroradiology, 2009
- Clinical investigations of polymethylmethacrylate cement viscosity during vertebroplasty and related in vitro measurementsEuropean Spine Journal, 2009
- Effects of Facetectomy and Crosslink Augmentation on Motion Segment Flexibility in Posterior Lumbar Interbody FusionSpine, 2008
- Kyphoplasty for treatment of osteoporotic vertebral fractures: a prospective non-randomized studyEuropean Spine Journal, 2004
- Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fracturesJournal of Neurosurgery: Spine, 2002
- Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects.1997