Two-year outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon: lessons from the bonus freeze protocol
Authors:
- 12 July 2015
- journal article
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 105 (1) , 72-78
Abstract
Pulmonary vein isolation (PVI) using the second-generation cryoballoon (CB2) in patients with paroxysmal and persistent atrial fibrillation (AF) has demonstrated encouraging acute and mid-term results. Follow-up data on outcome beyond 1-year is lacking. The purpose of this analysis was to investigate the 2-year clinical outcome after CB2-based PVI. Sixty patients (age 62 ± 11 years) with paroxysmal [45/60 (75 %) patients] or short-standing persistent AF [15/60 (25 %) patients] underwent 28-mm CB2-based PVI. Freeze-cycle duration was 240 s. After successful PVI, a bonus freeze-cycle of the same duration was applied. Follow-up was based on outpatient clinic visits at 3, 6, 12, 18, and 24 months including 24 h Holter-ECGs and telephone interviews. Recurrence was defined as any symptomatic and/or documented atrial tachyarrhythmia (ATA) episode >30 s following a 3-month blanking period. A total of 231 pulmonary veins (PV) were identified and 230/231 (99.6 %) PVs were successfully isolated. Phrenic nerve palsy occurred in 2/60 (3.3 %) patients. No other periprocedural complications occurred. Follow-up was available for 59/60 (98 %) patients with a mean duration of 838 ± 67 days. A total of 43/59 (73 %) patients remained in stable sinus rhythm. In 10/16 (63 %) patients with ATA recurrence, a repeat procedure was performed using radiofrequency energy. The overall success rate after a maximum of two ablation procedures and a follow-up period of 838 ± 67 days was 88 % (52/59) patients. Patients with paroxysmal or short-persistent AF undergoing PVI using the 28-mm CB2 demonstrated a 73 % 2-year single-procedure clinical success rate.Keywords
This publication has 17 references indexed in Scilit:
- Durability of Pulmonary Vein Isolation with Cryoballoon Ablation: Results from the Sustained PV Isolation with Arctic Front Advance (SUPIR) StudyJournal of Cardiovascular Electrophysiology, 2015
- One-year clinical success of a ‘no-bonus’ freeze protocol using the second-generation 28 mm cryoballoon for pulmonary vein isolationEP Europace, 2015
- Circumferential pulmonary vein isolation as index procedure for persistent atrial fibrillation: a comparison between radiofrequency catheter ablation and second-generation cryoballoon ablationEP Europace, 2015
- Pulmonary vein isolation as index procedure for persistent atrial fibrillation: One-year clinical outcome after ablation using the second-generation cryoballoonHeart Rhythm, 2015
- Improved 1‐Year Clinical Success Rate of Pulmonary Vein Isolation with the Second‐Generation Cryoballoon in Patients with Paroxysmal Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2014
- The Incidence of Phrenic Nerve Injury During Pulmonary Vein Isolation Using the Second‐Generation 28 mm CryoballoonJournal of Cardiovascular Electrophysiology, 2014
- Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-upEP Europace, 2014
- Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: A comparison between the first- and second-generation balloonHeart Rhythm, 2013
- Increased Incidence of Esophageal Thermal Lesions Using the Second-Generation 28-mm CryoballoonCirculation: Arrhythmia and Electrophysiology, 2013
- Long-Term Results of Catheter Ablation in Paroxysmal Atrial FibrillationCirculation, 2010