Automated assays for von Willebrand factor activity
- 28 December 2018
- journal article
- research article
- Published by Wiley in American Journal of Hematology
- Vol. 94 (4) , 496-503
Abstract
Von Willebrand factor (VWF) ristocetin cofactor activity (VWF:RCo) by platelet aggregometry has been considered the gold standard for evaluating the ability of VWF to bind platelets for over 40 years. Many automated systems no longer require platelets and rather rely on agglutination of latex particles. Automated methods of measuring VWF activity have improved performance characteristics and are performed on the same coagulation instruments used for routine testing via immunoturbidimetric methodology. Alternatively, a newer chemiluminescence assay system for measuring VWF activity demonstrates excellent performance characteristics. As these methods are becoming widely used, it is important to assess their performance in diagnosing and monitoring different types of von Willebrand disease. We review the automated methodologies and the published performance of these VWF assays. Advantages and limitations of these automated methods are discussed.Keywords
This publication has 40 references indexed in Scilit:
- A comparative evaluation of a new automated assay for von Willebrand factor activityHaemophilia, 2012
- Screening for von Willebrand disease: contribution of an automated assay for von Willebrand factor activityHaemophilia, 2011
- von Willebrand Factor Assay Proficiency TestingAmerican Journal of Clinical Pathology, 2011
- Gain-of-function GPIb ELISA assay for VWF activity in the Zimmerman Program for the Molecular and Clinical Biology of VWDBlood, 2011
- Validation of improved performance characteristics for the automated von Willebrand factor ristocetin cofactor activity assayJournal of Thrombosis and Haemostasis, 2010
- Common VWF exon 28 polymorphisms in African Americans affecting the VWF activity assay by ristocetin cofactorBlood, 2010
- A New Automated Screening Assay for the Diagnosis of von Willebrand DiseaseAmerican Journal of Clinical Pathology, 2007
- External Peer Review Quality Assurance Testing in von Willebrand Disease: The Recent Experience of the United States College of American Pathologists Proficiency Testing ProgramSeminars in Thrombosis and Hemostasis, 2006
- Comparison of a new automated von Willebrand factor activity assay with an aggregation von Willebrand ristocetin cofactor activity assay for the diagnosis of von Willebrand diseaseBlood Coagulation & Fibrinolysis, 2006
- Quantitative Assay of a Plasma Factor Deficient in von Willebrand's Disease that is Necessary for Platelet Aggregation. RELATIONSHIP TO FACTOR VIII PROCOAGULANT ACTIVITY AND ANTIGEN CONTENTJournal of Clinical Investigation, 1973