Evaluation of the Audicor Acoustic Cardiography Device as a Diagnostic Tool in Horses with Mitral or Aortic Valve Insufficiency
Open Access
Abstract
Mitral and aortic valve insufficiencies have been commonly reported in horses. The objective of this study was to establish the use of acoustic cardiography (Audicor®) in horses with aortic (AI) or mitral valve insufficiency (MI). A total of 17 healthy horses, 18 horses with AI, and 28 horses with MI were prospectively included. None of the horses was in heart failure. Echocardiography and Audicor® analyses were conducted. Electromechanical activating time (EMAT), rate-corrected EMATc, left ventricular systolic time (LVST), rate-corrected LVSTc, and intensity and persistence of the third and fourth heart sound (S3, S4) were reported by Audicor®. Graphical analysis of the three-dimensional (3D) phonocardiogram served to visually detect murmurs. Audicor® snapshot variables were compared between groups using one-way ANOVA followed by Tukey’s multiple-comparisons test. The association between Audicor® snapshot variables and the corresponding echocardiographic variables was investigated by linear regression and Bland–Altman analyses. Heart murmurs were not displayed on Audicor® phonocardiograms. No significant differences were found between Audicor® variables obtained in clinically healthy horses and horses with valvular insufficiency. The Audicor® device is unable to detect heart murmurs in horses. Audicor® variables representing cardiac function are not markedly altered, and their association with corresponding echocardiographic variables is poor in horses with valvular insufficiency that are not in heart failure.Keywords
This publication has 40 references indexed in Scilit:
- Noninvasive Prediction of Left Ventricular Systolic Dysfunction in Patients With Clinically Suspected Heart Failure Using Acoustic CardiographyCongestive Heart Failure, 2010
- Effect of left‐sided valvular regurgitation on mortality and causes of death among a population of middle‐aged and older horsesVeterinary Record, 2009
- Association of the Fourth Heart Sound With Increased Left Ventricular End-Diastolic StiffnessJournal of Cardiac Failure, 2008
- Noninvasive Detection of Left Ventricular Systolic Dysfunction by Acoustic Cardiography in Cardiac Failure PatientsJournal of Cardiac Failure, 2008
- Heart Murmurs and Valvular Regurgitation in Thoroughbred Racehorses: Epidemiology and Associations with Athletic PerformanceJournal of Veterinary Internal Medicine, 2008
- Methods and reliability of echocardiographic assessment of left atrial size and mechanical function in horsesAmerican Journal of Veterinary Research, 2007
- Hemodynamic Correlates of the Third Heart Sound and Systolic Time IntervalsCongestive Heart Failure, 2006
- Systolic Dysfunction: Correlation of Acoustic Cardiography With Doppler EchocardiographyCongestive Heart Failure, 2006
- Phonocardiography in the Horse: 2. The Relationship of the External Phonocardiogram to Intracardiac Pressure and SoundEquine Veterinary Journal, 1979
- Phonocardiography in the Horse: 1. The Intracardiac PhonocardiogramEquine Veterinary Journal, 1979