Analysis of flavonoids by CE using capacitively coupled contactless conductivity detection
- 21 February 2007
- journal article
- ce and-cec
- Published by Wiley in Electrophoresis
- Vol. 28 (5) , 799-805
Abstract
A CE method employing capacitively coupled contactless conductivity (C4D) compared to indirect UV‐detection was developed for the analysis of phytochemically relevant flavonoids, such as 6‐hydroxyflavone, biochanin A, hesperetin and naringenin. To ensure fast separation at highest selectivity, sensitivity and peak symmetry, the pH value and the concentration of the running BGE had to be optimized regarding both co‐ and counter‐EOF mode. Optimum conditions were found to be 1.0 and 5.0 mM chromate BGE (pH 9.50) in the counter‐ and co‐EOF mode, respectively. Validation of the established CE‐C4D method pointed out to be approximately seven times more sensitive compared to indirect UV‐detection applying the same conditions. The lower LOD defined at an S/N of 3:1 was found between 0.12 and 0.21 µg/mL for the analytes of interest using C4D and between 0.77 and 1.20 µg/mL using indirect UV‐detection. Compared to an earlier published CE method employing direct UV‐detection, C4D was found to be approximately two times more sensitive. Due to the lower baseline noise, C4D showed an excellent regression coefficient >0.99 compared to 0.93 when using indirect UV detection calibrating within a concentration range between 1 and 10 µg/mL. The influence of the sugar moiety on the conductivity of a flavonoid was studied upon the analysis of the aglycon hesperetin and the rutinosid hesperidin. The sugar moiety in hesperedin shows a higher conductivity compared to hesperetin. Finally, the optimized established CE‐C4D method was applied to the determination and quantification of naringenin in Sinupret®.Keywords
This publication has 45 references indexed in Scilit:
- Determination of different classes of amines with capillary zone electrophoresis and contactless conductivity detectionElectrophoresis, 2006
- Determination of vitamin C and preservatives in beverages by conventional capillary electrophoresis and microchip electrophoresis with capacitively coupled contactless conductivity detectionElectrophoresis, 2005
- Understanding Capacitively Coupled Contactless Conductivity Detection in Capillary and Microchip Electrophoresis. Part 2. Peak Shape, Stray Capacitance, Noise, and Actual ElectronicsElectroanalysis, 2005
- Precision improvement for the analysis of flavonoids in selected Thai plants by capillary zone electrophoresisElectrophoresis, 2005
- Separation of flavonoids and phenolic acids from propolis by capillary zone electrophoresisElectrophoresis, 2004
- Fast determination of flavonoids in Glycyrrhizae radix by capillary zone electrophoresisAnalytica Chimica Acta, 2002
- Simultaneous separation of inorganic anions and cations using capillary electrophoresis with a movable contactless conductivity detectorThe Analyst, 2002
- Determination of inorganic anions in Kraft pulping liquors by capillary electrophoresisJournal of High Resolution Chromatography, 1996
- Influence of organic solvents in coelectroosmotic capillary electrophoresis of phenolsAnalytical Chemistry, 1995
- Separation of cresols using coelectroosmotic capillary electrophoresisElectrophoresis, 1993